calibratioN:

 

The integrated multi-channel color sensor is calibrated by a 

 

white  calibration.  After  performing  a  white  calibration  the  

 

device is long term stable. We recommend to make a white  

 

calibration  before  every  measurement  series,  to  ensure  the  

 

device is calibrated correctly. 

 

StaNDarDS:

 

The  measurement  device  is  manufactured  according  to  the 

 

recommendations  of  the  technical  standards  DIN  5033  part  

 

1-9, CIE and ISO 5-3. 

 

The accuracy of the device is checked during the manufactur- 

 

ing by spectral measurements on color samples which were  

 

measured and certified by the German Institute for Material  

 

Testing (Bundesanstalt für Materialprüfung, BAM).

 

The calculation of densitometric values is according to the for- 

 

mulas and tables of ISO 5-3 and the handbook of standardiza- 

 

tion of the German Printing and Media Industries Federation  

 

(Bundesverband  Druck  und  Medien  e.  V.)  and  Fogra  (For- 

 

schungsgemeinschaft Druck e. V.).

Place                                               Date                                          Signature 

D-61462 Königstein

Summary of Contents for DENS

Page 1: ...Manual Color Densitometer DENS...

Page 2: ...can not fully guarantee the complete absence of errors TECHKON GmbH and the authors can not be held liable neither for any possibly incorrect statements nor their consequences Products that are not m...

Page 3: ...5 minutes you will know how to work with DENS The second chapter will show you detailed insight into the measurement functions Please get the device registered by using the registration card which you...

Page 4: ...orking with DENS 9 1 5 Care and maintenance 11 ChaptEr 2 Description of the measurement functions 2 1 Measurement function D 14 2 2 Measurement function D 15 2 3 Measurement function T 16 2 4 Measurem...

Page 5: ...amental densitometric quality control on the basis of the reliable high accuracy well known from all TECHKON instruments The DENS indicates densities dot area and gray balance clearly legible on a lar...

Page 6: ...user friendly measurement button Durable precision Handy and compact low weight Well designed Two different versions We supply TECHKON DENS in two device versions DENS Status ISO E Pol Density filter...

Page 7: ...manual A comprehensive DENS manual can be downloaded under www techkon com index php dens html Optional accessories Print Control Strip TECHKON TCS the Digital Print Control Strips TECHKON TCS can be...

Page 8: ...r at the side of the device is part of the package K C M Y 80 40 0 K C M Y K C M Y 80 40 0 K C K C K C M Y K C M Y K C M Y BAL BAL C M BAL BAL C Y M Y BAL M Y BAL 0 BAL K 5 4 3 2 80 40 80 40 80 40 80...

Page 9: ...ttery status is displayed as a battery symbol with three segments in the lower right corner of the display when the device is turned on When the battery turns empty the last remaining segment of the b...

Page 10: ...working properly For density measurements according to Status ISO E Pol the calibration is carried out on paper white This will ensure that the density values are in direct ratio to the ink thickness...

Page 11: ...y labels at the bottom of the device This could lead to faulty measurements because the direct contact which is important for the correct optical field of depth might not be maintained Warranty The wa...

Page 12: ...evice case 4 When reassembling do not tighten the screws too much otherwise they might break Replacement of the rechargeable battery The rechargeable Li Ion battery has a high lifespan However after a...

Page 13: ...ch of the reference and press the CAL but ton 3 Place the measurement head on the Cyan solid density patch of the reference and press the DENS button 4 The desired value can be set respectively by pre...

Page 14: ...tween 1 00 and 2 00 Chapter 2 Description of the measurement functions The current measurement function is indicated on the right side of the display A switch to the next mode is done by pressing the...

Page 15: ...posed of different portions of Cyan Magenta and Yellow It does not include black ink 1 Measurement 2 Measurement 2 2 Measurement function D Dot area measurement in reflection For the function Dot Area...

Page 16: ...he luminosity of the light table Av erage bright light tables allow you to measure densities up to D 4 00 and over Please note The emulsion side of the film has to be always on the upper side 2 4 Meas...

Page 17: ...nt time 0 5 seconds per measurement White reference Relative ISO E or absolute ISO T Density filter ISO E with polarization filter optional ISO T without polarization filter Density measurement range...

Page 18: ...s maintenance free The measurement aperture has to be kept clean from dust It can be cleaned with clean compressed air and an optics brush We recommend a functionality check up every 24 months at the...

Page 19: ...al standards DIN 5033 part 1 9 CIE and ISO 5 3 The accuracy of the device is checked during the manufactur ing by spectral measurements on color samples which were measured and certified by the German...

Page 20: ...anforderungen gem eu richtlinie 2004 108 ec entspricht und dass die folgenden Normen angewandt wurden complies with the essential requirements of the 2004 108 EC Directive if used for its intended us...

Page 21: ...Please put my E mail address on the mailing list for the TECHKON Newsletter TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein Via telefax to 49 0 6174 9244 99 Please send this registration card by ma...

Page 22: ...TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein T 49 0 6174 924450 F 49 0 6174 924499 info techkon com www techkon com Erfolg ist messbar...

Reviews: