– How to use TECHKON DENS

1.5 Care and maintenance

DENS is a highly-precise optical instrument. It is designed to work in harsh, industrial 
environments.  However,  it  should  be  handled  with  care.  Avoid  mechanical  shocks, 
heat, dusty or humid environments. 

Cleaning

The measurement head with the optical system is sealed against dust and dirt. Take 
nevertheless care that the visible, open measurement aperture is always free of dust. 
You can clean the measurement aperture with oil-free, clean compressed air and a 
brush used for cleaning photographic equipment.

Clean the device casing and the display window only with a soft cloth and a non-
aggressive plastic cleaner. Never use alcohol or chemically aggressive solvent-based 
cleaners which can destroy the surfaces.

Please do not stick any labels at the bottom of the device. This could lead to faulty 
measurements, because the direct contact – which is important for the correct optical 
field of depth – might not be maintained

Warranty

The warranty for TECHKON products is 24 months starting with the date of purchase. 
The invoice is the certificate of warranty. The warranty is invalid if the damage is caused 
by inadequate use of the device.

Should a TECHKON product do not work according to the specification, please contact 
us before sending us the device. In most cases we can solve the problem over the 
phone or via E-mail.

Inspection intervals

TECHKON DENS is maintenance free. We recommend to

 validate the complete func-

tionality of the devices in a 24 months time interval

 in the TECHKON service cen-

ter.

Please send the device always securely in the original packing. For a flat fee the device 
will be cleaned, checked and recalibrated. In case a repair or exchange of components 
should be necessary we will inform you in advance. 

Summary of Contents for DENS

Page 1: ...Manual Color Densitometer DENS...

Page 2: ...can not fully guarantee the complete absence of errors TECHKON GmbH and the authors can not be held liable neither for any possibly incorrect statements nor their consequences Products that are not m...

Page 3: ...5 minutes you will know how to work with DENS The second chapter will show you detailed insight into the measurement functions Please get the device registered by using the registration card which you...

Page 4: ...orking with DENS 9 1 5 Care and maintenance 11 ChaptEr 2 Description of the measurement functions 2 1 Measurement function D 14 2 2 Measurement function D 15 2 3 Measurement function T 16 2 4 Measurem...

Page 5: ...amental densitometric quality control on the basis of the reliable high accuracy well known from all TECHKON instruments The DENS indicates densities dot area and gray balance clearly legible on a lar...

Page 6: ...user friendly measurement button Durable precision Handy and compact low weight Well designed Two different versions We supply TECHKON DENS in two device versions DENS Status ISO E Pol Density filter...

Page 7: ...manual A comprehensive DENS manual can be downloaded under www techkon com index php dens html Optional accessories Print Control Strip TECHKON TCS the Digital Print Control Strips TECHKON TCS can be...

Page 8: ...r at the side of the device is part of the package K C M Y 80 40 0 K C M Y K C M Y 80 40 0 K C K C K C M Y K C M Y K C M Y BAL BAL C M BAL BAL C Y M Y BAL M Y BAL 0 BAL K 5 4 3 2 80 40 80 40 80 40 80...

Page 9: ...ttery status is displayed as a battery symbol with three segments in the lower right corner of the display when the device is turned on When the battery turns empty the last remaining segment of the b...

Page 10: ...working properly For density measurements according to Status ISO E Pol the calibration is carried out on paper white This will ensure that the density values are in direct ratio to the ink thickness...

Page 11: ...y labels at the bottom of the device This could lead to faulty measurements because the direct contact which is important for the correct optical field of depth might not be maintained Warranty The wa...

Page 12: ...evice case 4 When reassembling do not tighten the screws too much otherwise they might break Replacement of the rechargeable battery The rechargeable Li Ion battery has a high lifespan However after a...

Page 13: ...ch of the reference and press the CAL but ton 3 Place the measurement head on the Cyan solid density patch of the reference and press the DENS button 4 The desired value can be set respectively by pre...

Page 14: ...tween 1 00 and 2 00 Chapter 2 Description of the measurement functions The current measurement function is indicated on the right side of the display A switch to the next mode is done by pressing the...

Page 15: ...posed of different portions of Cyan Magenta and Yellow It does not include black ink 1 Measurement 2 Measurement 2 2 Measurement function D Dot area measurement in reflection For the function Dot Area...

Page 16: ...he luminosity of the light table Av erage bright light tables allow you to measure densities up to D 4 00 and over Please note The emulsion side of the film has to be always on the upper side 2 4 Meas...

Page 17: ...nt time 0 5 seconds per measurement White reference Relative ISO E or absolute ISO T Density filter ISO E with polarization filter optional ISO T without polarization filter Density measurement range...

Page 18: ...s maintenance free The measurement aperture has to be kept clean from dust It can be cleaned with clean compressed air and an optics brush We recommend a functionality check up every 24 months at the...

Page 19: ...al standards DIN 5033 part 1 9 CIE and ISO 5 3 The accuracy of the device is checked during the manufactur ing by spectral measurements on color samples which were measured and certified by the German...

Page 20: ...anforderungen gem eu richtlinie 2004 108 ec entspricht und dass die folgenden Normen angewandt wurden complies with the essential requirements of the 2004 108 EC Directive if used for its intended us...

Page 21: ...Please put my E mail address on the mailing list for the TECHKON Newsletter TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein Via telefax to 49 0 6174 9244 99 Please send this registration card by ma...

Page 22: ...TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein T 49 0 6174 924450 F 49 0 6174 924499 info techkon com www techkon com Erfolg ist messbar...

Reviews: