![TechGrow Humi Heavy User Manual Download Page 10](http://html1.mh-extra.com/html/techgrow/humi-heavy/humi-heavy_user-manual_1066477010.webp)
____________________________________________________________________________________________________________________________
Tech
Grow
| Innovative Growing Solutions
10
8. Switching between humidification
and dehumidification
Turn on the Humi Heavy again.
The display shows:
Humi Heavy
V 1.0
After a few seconds you will see:
Select function
Up or Down
Here you can set how the Humi Heavy should function
by turning de PTK.
If you select "Up", the Humi Heavy will be suitable for a
humidifier.
If you select "Down", the Humi Heavy will be suitable
for a dehumidifier.
Confirm by pressing the PTK.
9. Setup setpoint & hysterese
Press the PTK once (briefly) to open the settings menu.
Set level & hyst
Set 50% Hys 3%
Here you can enter the desired values.
The cursor is in front of Set.
You can set the desired value by turning the PTK.
Press again and the cursor will move to Hys.
You can set the desired value by turning the PTK.
By pressing the PTK again, the data is stored in the
memory.
10. Replace the fuse
If the Humi Heavy is overloaded or in the event of a
short circuit, the internal fuse will break. To replace the
fuse you have to open the Humi Heavy. Go through the
following steps:
1.
Remove the plug from the socket.
2.
Open the housing by unscrewing the 4 screws on
the back of the Humi Heavy.
3.
Locate the fuse and remove it.
4.
Insert a new 10 amp fuse.
5.
Screw the 4 screws to close the housing.
6.