background image

Introduction 

 

RFID reader WREM 81 MTM(VR) with wiegand output, reads media at 125 kHz (EM 
Marin) and is designed for connection to control modules and door controllers of the 
APS mini Plus or APS 400 system, or to third party controllers. The reader is equipped 
with a configurable WIEGAND data output usable with most third party systems. The 
reader is delivered in MTMRFID module dedicated for entry panel MTM. It contains two 
inputs (LED and buzzer control), as well as an 
RS 485 interface for configuring the wiegand output or fw update. 

 

 

a.  Application 

 

 

Access control system, booking system 

 

Door access control, both-sided access control 

 

Lift access control 

 

b.  Parameters 

 

 

Input voltage 8 ÷ 28 Vdc 

 

Typical current consumption 53 mA @ 12 V 

 

Maximum input power 1,1 W 

 

Reading ID media EM Marin, Jablotron 

 

1x RS 485 (update firmware, wiegand output format settings) 

 

1x Wiegand output (length 24 

– 56 bits, MSB / LSB, reverse option) 

 

2x Input (LED, buzzer control) 

 

Integrated in module MTMRFID (entry panel MTM) 

 

VR 

– antivandal option, black zamak alloy 

 

c.  Variants 

Product variants in aluminium, silver color 

CATALOG NUMBER 

PART NUMBER 

SYSTEM 

VARIANT 

RFID frequency 

51481C01 

WREM 81 MTM - EM 

APS mini Plus 

Modul MTMRFID 

125 kHz 

 
Product variants in zamak, black color 

CATALOG NUMBER 

PART NUMBER 

SYSTEM 

VARIANT 

RFID frequency 

51481011 

WREM 81 MTMVR - EM 

APS mini Plus 

Modul MTMRFID 

125 kHz 

 
 

d. 

Marking

 

 

 
 
 
 
 
 
 
 

 

MIFARE

®

 a MIFARE Classic

®

 are registered trademarks owned by NXP B.V. 

Android

®

 is registered trademark owned by Google LLC. 

Summary of Contents for WREM 81 MTM

Page 1: ...WREM 81 MTM VR RFID reader 13 56 MHz 125 kHz...

Page 2: ...ess control b Parameters Input voltage 8 28 Vdc Typical current consumption 53 mA 12 V Maximum input power 1 1 W Reading ID media EM Marin Jablotron 1x RS 485 update firmware wiegand output format set...

Page 3: ...stem it has its own power supply and bus for receivers WREM 81 MTM VR has its own cabling configuration bus and wiegand interface for door controller or APS mini Plus or APS 400 reader module or third...

Page 4: ...The reader can be configured via the RS 485 bus using the APSUSB converter and the program APS Reader...

Page 5: ...2 2 Installation instructions 8 3 RFID reading 9 3 1 Reading at 125 kHz 9 3 2 Wiegand output configuration 9 4 Wiring diagram 10 4 1 Connection possibilities WREM 81 MTM VR 10 5 Settings 12 5 1 Setup...

Page 6: ...SO card 125 kHz EM Marin 3 5 cm Signalization RGB led Piezo 1 1 pc 1 2 Communication interface INTERFACE DESCRIPTION TECHNOLOGY PROPERTIES Service data bus RS 485 19 200 bit s 8 datov ch bit sud parit...

Page 7: ...wer supply Vout dc 4 Pink Wiegand data 1 Wiegand input MWGD 82 5 Green Wiegand data 0 Wiegand input MWGD 82 6 Gray Input 2 IN 2 LED control MWGD 82 7 Yellow Input 1 IN 1 buzzer control MWGD 82 8 Brown...

Page 8: ...y to wiegand interface this bus must be connected in one twisted pair The actual configuration is performed using eg the APSUSB converter and the APS Reader program 2 2 3 Radio signal interferences If...

Page 9: ...ng 3 1 Reading at 125 kHz The device read media on a frequency of 125 kHz like EM Marin e g EM4200 EM4305 Next example of supported media technology is Jablotron ID 125 kHz settings possibilities Defa...

Page 10: ...use the desktop application APS Reader FIGURE B Connection WREM 81 MTM VR to the wiegand door controller The Wiegand output of the reader is connected to the Wiegand input of the door controller eg MW...

Page 11: ...WREM 81 MTM VR to the MTM entry panel you can use your own access control system power supply Connect the wiegand interface power supply minimum and if possible the signal for LED and buzzer control a...

Page 12: ...techfass com cs produkty 101 produkt 389 aps reader 5 2 Indicative parts RGB LED and buzzer PART ACTION DESCRIPTION Red LED Continuously lit Power supply Green LED Flash ID media reading lock release...

Page 13: ...its MSB 32 data bits MSB 32 data bits reversed LSB 32 data bits reversed LSB 32 data bits reversed LSB 24 data bits MSB 24 data bits MSB 24 data bits MSB Facility code 0x01 16 data bits MSB Facility c...

Page 14: ...2 Declaration of conformity The manufacturer TECH FASS ltd declares that the product follows legal requirements and fulfils necessary European directives The declaration of conformity document can be...

Page 15: ...TECH FASS s r o V t nsk 1611 19 Praha...