www.techfass.com
RFID reader
WREM 81 MTM(VR)
7
2 Assembly
2.1 Cable connection of WREM 81 MTM(VR)
Cable of WREM 81 MTM(VR) contents 12 wires with following functions:
WREM 81 MTM(VR)
NUMBER
COLOR
DESCRIPTION
WHERE TO CONNECT (example)
1
Purple
Do not connect
2
Blue
Power GND
Power supply GND
3
Red
Power
Vin 8 ÷ 28 Vdc
Power Vout dc
4
Pink
Wiegand data 1
Wiegand input MWGD 82
5
Green
Wiegand data 0
Wiegand input MWGD 82
6
Gray
Input 2 (IN 2), LED control
MWGD 82
7
Yellow
Input 1 (IN 1), buzzer control
MWGD 82
8
Brown
Signal ground 0 V
GND for inputs or RS 485
9
White
Signal B, configuraton, fw update
APSUSB*
10
Black
Signál A configuration, fw update
APSUSB*
*Configuration, firmware update.
** LED a Buzzer is possible to control by one wire together.
2.1.1 Inputs
INPUTS
DESCRIPTION
Vstup 1 (IN 1)
Ovládání bzučáku
Vstup 2 (IN 2)
Ovládání LED