12. Clean components in an ultrasonic bath:
•
Place the nozzle bushing, tappet bushing, adjustment nut and tappet
seal in a beaker. Fill the beaker with appropriate cleaning solvent
until all parts are covered. Place the beaker in the ultrasonic bath
for 15 – 20 minutes.
•
Place the fluid manifold, fluid box adapter, luer-lock fitting, and
locking screw in a separate beaker. Fill the beaker with appropriate
cleaning solvent until all parts are covered. Place the beaker in the
ultrasonic bath for 15 – 20 minutes.
•
Place the nozzle insert and tappet in a separate beaker. Fill the
beaker with appropriate cleaning solvent until all parts are covered.
Place the beaker in the ultrasonic bath for 15 – 20 minutes.
13. After ultrasonic cleaning, remove components from cleaning solvent and
dry them using compressed air.
14. The thorough cleaning process is completed. Re-assemble the valve by
following steps 10 – 2.