5. Touch the up and down arrows to set the desired temperature. Then touch
the ‘Accept’ icon to save and exit.
Note
: Maximum temperature
setting is 90°C.
6. Watch the fluid manifold’s temperature reading at the bottom of the
screen. . Once this temperature reaches the temperature setting,
then start the dispensing.
Caution:
Do not touch nozzle or fluid manifold with your fingers once
the heater is turned on. Use provided tools for making any adjustment if
necessary.
7.
Touch the ‘Temperature’ icon
again to turn the heater OFF and the
icon will turn back to green.
23
Jet Valve Dispensing System User Guide
TS9800
& TS980