6-16
6. DIAG. TEST OPERATION
EM18-33011
6.3.3
Back Feed Length Fine Adjustment
6.3 PARAMETER SETTING MODE
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
Press the [FEED] key.
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key three times.
Press the [PAUSE] key.
B A
A D J .
+ 0 . 0 m m
C
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Continued on Section 6.3.4
X axis fine adjustment.
Press the [FEED] key
and [RESTART] key
at the same time.
K
[FEED] key:
Pressing the [FEED] key one
time is a -0.5 mm change, up to
-9.5 mm. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +0.5 mm change, up to
+9.5 mm. (See NOTE 2.)
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. Max. fine adjustment
±
9.9 mm = Key fine adjustment value (
±
9.5 mm) + PC fine adjustment
value (
±
9.9 mm)
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3. A changed back feed value is stored in memory by pressing the [PAUSE] key.