Technical manual of 

FanControl-U2 module

8

The default value is 3 (30 minutes). To exit the programming mode turn off the ignition or wait 

for 30 seconds after the last press on the programming button was made.

The value of this option is ignored if the module is controlled via the status external control 

input №11 (pink/black). The module remains activated until the signal is present at the 

input, but for no longer than 120 minutes.

Auxiliary heater mode

In this mode an aftermarket self-contained heater operates according to the algorithms of an 

OEM auxiliary engine heater: if the ambient temperature is below 5°С, the module will autmatically 

switch into the auxiliary heating mode. If the ambient temperature rises above 12 °C, the heater 

will switche off automatically.

To activate/deactivate the auxiliary heating mode switch the vehicle's ignition ON and press the 

programming button 12 times (a standard button or the built-in one). The module shall indicate 

the option №12 "Auxiliary heater mode" status (refer to the table 3 "System setup") as follows:

• 

1 LED flash – the auxiliary heater mode is ON;

• 

2 LED flashes – the auxiliary heater mode OFF (the default value).

W‑BUS/Eberspächer protocol selection

In most cases, the protocol is assigned automatically when you connect the system to a heater. 

Manual selection of the protocol is required in exceptional cases. Programming is performed only 

by the built-in button (see Figure 2). In order to select a protocol switche the ignition on, press the 

programming button 6 times. The module shall inform about the item status by series of flashes:

• 

1 signal – protocol is not set (factory settings).

• 

2 signals – W-BUS.

• 

3 signals – Eberspächer

• 

4 signals 

 control is disabled.

Change item status by pressing the programming button as many times as it is required. The 

module exits programming mode in 15 seconds after the last button-pressing. Upon successful 

saving of settings, the LED would flash 4 times; 1 long flash means an error.

Set heat‑up temperature limit for aftermarket heater

This option is used with some vehicles in exceptional cases. You may find recommendation 

to use it in the corresponding manual (check www.tecel.ru/en/ or www.canbus-alarm for latest 

manuals).

To change this option press programming button 15 times. Module will inform about its state 

with series of LED flashes:

• 

1 flash – off (factory default)

• 

2 flashes – 71°C

• 

3 flashes – 73°C

• 

4 flashes – 75°C

• 

5 flashes – 77°C

• 

6 flashes – 79°C

• 

7 flashes – 81°C

• 

8 flashes – 83°C

• 

9 flashes – 85°C.

Summary of Contents for FanControl-U2

Page 1: ...www tecel ru FanControl U2 Technical manual...

Page 2: ...84 3 E90 X5 E70 X5 F15 X6 E71 6 63 64 X4 F26 X6 F16 X1 F48 7 G11 G12 5 G30 Mini Cooper 2014 Countryman F60 2017 Land Rover Range Rover Vogue 2013 Range Rover Vogue 2014 Range Rover Sport 2014 Discover...

Page 3: ...al data bus 4 Grey blue LIN 2 Serial data bus 5 Blue yellow Digital bus Special bus for controlling Webasto Thermo Top C Evo5 Eberspacher D5WS heaters Can be used for control of aftermarket heaters an...

Page 4: ...programming can also be carried out either with a programming button one of the vehicle s interior buttons the information on which button is used on a particular vehicle is available at www tecel ru...

Page 5: ...as no data entry module will leave programming mode Connection to CAN bus Connection types There are two types of module connection to CAN bus Parallel connection It is used to control factory heaters...

Page 6: ...Automatic identification 2 Webasto 3 Ebersp cher 4 Protocol control is forbidden 5 Factory Webasto heater alternative protocol for VAG 6 Factory Webasto heater for RR Evoque 2011 2013 7 Factory Ebersp...

Page 7: ...heater mode is activated 6 Cooling system loop switching valve control The output generates a constant level signal after the engine heater is turned ON The output stops generating the signal in 20 m...

Page 8: ...de OFF the default value W BUS Ebersp cher protocol selection In most cases the protocol is assigned automatically when you connect the system to a heater Manual selection of the protocol is required...

Page 9: ...ng Technical data and operating conditions Table 4 Package contents Name Value Supply voltage V 9 15 Maximum current draw in operating mode mA 200 Maximum current draw in standby mode mA 2 5 Temperatu...

Reviews: