Technical manual of 

FanControl-U2 module

6

Switch the module on/off with the external input  

Status control 

*

12V
0V
Оn
Off

Input #11

FanControl

*

  To restart the module via input #11 it is necessary to switch off the “status” signal and then 

activate it again.

   

 

Trigger control

12V
0V

Input #9

FanControl

On
Off

Programming sequence

1. 

Choose required option in table 3. Then press PB amount of times corresponding to menu 

code. LED will inform you about it’s state.

2. 

Change option state. To do so press PB required amount of times, required to change the 

option value to the chosen one. Mind that the first value, goes after last value.

System will leave programming mode and save all changes after turning off the ignition or 

after  15 seconds after last button press. LED will flash 4 times if settings are saved succesfully 

or 1 time if there is an error during save.

Table 3. System setup

Menu

Menu 

code

Factory 

default

Note

Protocol

W-BUS/Eberspächer

6

1

Set automatically. Choose by hand if required.
1 – Automatic identification; 2 – Webasto;

3 – Eberspächer;

4 – Protocol control is forbidden;

5 – Factory Webasto heater alternative protocol 

for VAG;

6  –  Factory  Webasto  heater  for  RR  Evoque 

(2011-2013);

7 – Factory Eberspächer for RR Evoque (2011-

2013)/Sport (2014-2015);

8 – Factory Eberspächer for Toyota;

9 – Factory Eberspächer for RR Sport (2016)

The vehicle battery 

voltage level for automaic 

system shut down

11

9

1 — 10,5 V; … 9 — 11,3 V; ... 11 — 11,5 V

Heater operation time

10

3

1–10 min; 2–20 min; 3–30 min; … 12–120 min

Supplementary (auxiliary) 

heater mode

12

2

If outside temperature is lower 5°C — an 

aftermarket heater will start automatically. If 

outside temperature increases to 12°C —  

heater will turn off.
1 — on; 2 — off

Climate sytem control 

algorithm

14

1

1 — standard

;

2 — alternate algorithm №1

*

;

3 — alternate algorithm №2

*

;

4 — alternate algorithm №3

*

Aftermarket heater 

temperature limiter

*

15

1

1 — disabled; 2 —  71°C;  3 —  73°C; … 9 —  85°C

Climate control setup

*

20

1

1 — enabled; 2 — disabled

Climatic system settings

24

1

1 — Activation immediately after a heater

is turned on

2 — Delayed activation after a heater is turned on

3 — Activation by temperature

4 — Activation after a delay or by temperature 

(depending on what comes first)

5 — Climatic system inactive

Summary of Contents for FanControl-U2

Page 1: ...www tecel ru FanControl U2 Technical manual...

Page 2: ...84 3 E90 X5 E70 X5 F15 X6 E71 6 63 64 X4 F26 X6 F16 X1 F48 7 G11 G12 5 G30 Mini Cooper 2014 Countryman F60 2017 Land Rover Range Rover Vogue 2013 Range Rover Vogue 2014 Range Rover Sport 2014 Discover...

Page 3: ...al data bus 4 Grey blue LIN 2 Serial data bus 5 Blue yellow Digital bus Special bus for controlling Webasto Thermo Top C Evo5 Eberspacher D5WS heaters Can be used for control of aftermarket heaters an...

Page 4: ...programming can also be carried out either with a programming button one of the vehicle s interior buttons the information on which button is used on a particular vehicle is available at www tecel ru...

Page 5: ...as no data entry module will leave programming mode Connection to CAN bus Connection types There are two types of module connection to CAN bus Parallel connection It is used to control factory heaters...

Page 6: ...Automatic identification 2 Webasto 3 Ebersp cher 4 Protocol control is forbidden 5 Factory Webasto heater alternative protocol for VAG 6 Factory Webasto heater for RR Evoque 2011 2013 7 Factory Ebersp...

Page 7: ...heater mode is activated 6 Cooling system loop switching valve control The output generates a constant level signal after the engine heater is turned ON The output stops generating the signal in 20 m...

Page 8: ...de OFF the default value W BUS Ebersp cher protocol selection In most cases the protocol is assigned automatically when you connect the system to a heater Manual selection of the protocol is required...

Page 9: ...ng Technical data and operating conditions Table 4 Package contents Name Value Supply voltage V 9 15 Maximum current draw in operating mode mA 200 Maximum current draw in standby mode mA 2 5 Temperatu...

Reviews: