Appendix A
Parameter overview
– setting ranges
299-020200-TWD01
14.07.2017
55
10
Appendix A
10.1 Parameter overview
– setting ranges
Welding
da
ta di
splay
(3
-digi
t)
Parameters/function
Setting range
Standa
rd
(e
x wo
rks
)
Mi
n.
Max.
Unit
TIG
Gas pre-flow time
0,2
0,1
-
5
s
Ignition current
20
1
-
200
%
Up-slope time
1,0
0,0
- 20,0
s
Secondary current AMP%
50
1
-
200
%
End current
30
1
-
200
%
Diameter of tungsten electrode/ignition optimisation
2,4
1
-
4
mm
AC balance
-10
30
-
-30
AC frequency
80
50
-
200
Hz
Pulse balance
50
1
-
99
%
Pulse frequency
2,8
0,2
-
5,0
Hz
Pulse current
140
1
-
200
%
MMA
Hot start current
150
1
-
150
%
Hot start time
0,1
0,0
-
5,0
s
Pulse balance
30
1
-
99
%
Pulse frequency
1,2
0,2
-
50
Hz
Pulse current
142
1
-
200
%
Basic parameters (independent of procedure)
Time-based power-saving mode
off
5
-
60
min.
Access control
– access code
000
000 -
999