Design and function
MMA welding
38
299-020200-TWD01
14.07.2017
5.4
MMA welding
5.4.1
Connecting the electrode holder and workpiece lead
CAUTION
Risk of crushing and burns!
When changing stick electrodes there is a risk of crushing and burns!
• Wear appropriate and dry protective gloves.
• Use an insulated pair of tongs to remove the used stick electrode or to move welded
workpieces.
Shielding gas connection!
During MMA welding open circuit voltage is applied at the shielding gas connection
(G¼" connecting nipple).
• Place yellow insulating cap on the G¼" connection nipple (protects against electrical
voltage and dirt).
Figure 5-22
Item Symbol
Description
0
1
Electrode holder
2
Connection socket, “-” welding current
Workpiece lead or electrode holder connection
3
Workpiece
4
Connection socket for "+" welding current
Electrode holder or workpiece lead connection
5
Connecting nipple G¼, shielding gas connection
Polarity depends on the instructions from the electrode manufacturer given on the electrode
packaging.
• Insert cable plug of the electrode holder into either the "+" or "-" welding current connection socket and
lock by turning to the right.
• Insert cable plug of the workpiece lead into either the "+" or "-" welding current connection socket and
lock by turning to the right.
• Fit yellow protective cap onto G¼" connecting nipple.