Machine description
– quick overview
Machine control
– Operating elements
16
299-020200-TWD01
14.07.2017
4.3
Machine control
– Operating elements
The setting ranges for the parameter values are summarised in the Parameter overview
section
> see 10.1 chapter
.
^
Figure 4-3
Item Symbol
Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 5.2 chapter
2
Error/status indicators
------
Collective interference signal light
--------- Water deficiency signal light (welding torch cooling)
--------- Excess temperature signal light
--------- S safety sign signal light
3
AMP
Main current signal light
Imin to Imax (1 A increments)
4
AMP%
Secondary current (TIG)
5
Welding parameter setting rotary dial
Setting currents, times and parameters.
6
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
7
sec
Down-slope time (TIG)