Design and function
Remote control
299-020200-TWD01
14.07.2017
41
Display
Setting/selection
Hotstart time
Pulse balance
Pulse frequency
Pulse current
> see 5.4.5 chapter
5.5
Remote control
The remote controls are operated on the 19-pole remote control connection socket (analogue).
5.5.1
TW-RT1 19POL
Functions
• Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
5.6
Interfaces for automation
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause damage
to the machine.
• Only use shielded control leads!
• If the machine is to be operated with control voltages connection via suitable isolation
amplifiers is required!
• To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).
5.6.1
Remote control connection socket, 19-pole
Figure 5-28