25
5. Connector specifications
5-2. SYNC IN and SYNC OUT connectors
Function
Use these input and output connectors for synchronized recording
with two systems. Do not connect anything when not conducting
synchronized recording.
Clock input and output
FS, MSYNC
Control input and output
RECTRG, SYNCTRG, COM
Status input and output
STS, SYNCERR, SYNCBUSY
Input and output circuit format
Serial communication
RS-422 (MAX4385 or equivalent)
Connector
Angled, half-pitch, 28-pin (Hirose DX10A-28S)
Pin assignments
Pin
Signal
Function
1
GND
Power supply 0 V
2
FS clock +
3
SYNCFS-
FS clock -
4
GND
Power supply 0 V
5
MSYNC+
Master clock +
6
MSYNC-
Master clock -
7
GND
Power supply 0 V
8
COM+
Command
9
COM-
Command signal -
10
GND
Power supply 0 V
11
STS+
Status
12
STS-
Status signal -
13
GND
Power supply 0 V
14
RESERVED
Reserved
15
GND
Power supply 0 V
16
SYNC t
17
SYNCTRG-
SYNC trigger -
18
GND
Power supply 0 V
19
Recording t
20
RECTRG-
Recording trigger -
21
GND
Power supply 0 V
22
S
SYNC busy +
23
SYNCBUSY-
SYNC busy -
21
GND
Power supply 0 V
25
SYNC error +
26
SYNCERR-
SYNC error -
27
GND
Power supply 0 V
28
RESERVED
Reserved
Summary of Contents for WX-7000
Page 1: ...WIDE BAND DATA RECORDER Owner s Manual Z WX 7000 D01190210J ...
Page 84: ...84 19 Exterior drawings WX 7016 340 348 10 8 220 13 8 123 82 40 15 WX 7032 164 82 40 40 15 ...
Page 85: ...85 WX 7064 246 82 40 40 40 40 15 WX 7096 360 370 396 19 Exterior drawings ...