43
10. Synchronization function
10-3. Synchronized recording settings
If you set the master unit SAMPLING FREQ, AD BIT and recording
destination, they will also be set for the slave unit automatically.
These cannot be changed from the slave unit.
The number of recording channels can be set separately for the mas-
ter and slave units. If recording is conducted at a transmission speed
greater than that at which the slave unit can record, a Synchro Error
will occur.
Confirm that the number of recording channels on the slave unit is
suitable before starting recording.
o
Setting triggers on the slave unit is not possible.
o
The following amount of time is necessary to start synchronized
recording from a stopped state.
Sampling frequency
Starting delay
192 kHz–6 kHz
About 4–7 seconds
3 kHz
About 20 seconds
1.5 kHz
About 25 seconds
o
Level triggers become effective 10 seconds after the unit
becomes record ready.
10-4. Synchronized playback settings
After selecting the file to play on the slave unit, select the file to play
on the master unit.
If you select the file to play on the master unit first, search by ID for
the file to play on the slave unit.
o
It is not possible to search the slave unit using methods other
than ID search. Use the master unit for other search methods.
o
The following amount of time is necessary to start synchronized
playback from a stopped state.
Sampling frequency
Starting delay
192 kHz–6 kHz
About 5 seconds
3 kHz–1.5 kHz
About 10 seconds
10-5. Confirming synchronization
connections
In the master unit SYSTEM menu, select SYNCHRO SETTING, and
press the VALUE knob to open the SYNCHRO SETTING screen.
Current
selection
Selection
Use the VALUE knob and the up, down, left and right (
5
,
b
,
g
,
t
)
buttons to change the selection.
Press the VALUE knob to change the setting of the selected parameter.