Vers. 001
Energy 2510 B
GB
11
Always fit a 100 A fuse
onto the positive cable connecting the
generating set to the positive pole of the
battery.
4.5 Electric Load connection
To connect loads to the power generating set,
use a three-pole cable up to the applicable
standards in force. The correct cross section is
shown in Table 1.
Table 1
Model
Sect. mm
2
line 230 V
Cable leng.
Lgth < 6 m
Cable leng
Lgth. > 6 m
2500B
2.5
10
16
LINE
CONNECTION 230 V
BATTERY
CONNECTION
For connection to the 230V input line, the
generating set is equipped with a special terminal
strip (Fig.13 Ref.1) to which the cables must be
connected.
Use the special cable outlet (Fig.11 Ref.1) to
prevent water seeping into the generating set.
Although the generating set is equipped with a
special internal thermal cut-out to cut power
delivery in the event of overload or short circuits
(Fig.13 Ref.5), it is advisable to install (in the
vehicle control panel) a thermomagnetic cut-out
switch, suitably set to stop power delivery to the
various users when current absorption exceeds
9.5
Amp for
ENERGY 2510 B
If the generating set thermal cut-out switch has
been operated, press the button (Fig. 7 Ref. 5) to
restore closed circuit and power delivery
conditions.
Carefully check the
position of the line connection for picking up
230 Volt current. Wrong connection could
damage the generating set irreparably or
create dangerous short circuits.