Racewell HD
SHEEP HANDLING SYSTEMS
DRAFTING THE WRONG WAY FOR PRESET WEIGHTS
Ensure the manual draft switch is in the auto position
Turn power off and on again on the Handler. This will
force a communication handshake between the scales
and handler
EVERYTHING WORKS APART FROM THE DRAFTER
Indicator not talking to drafter
Check comms cable between indicator and autobox
for damage
Turn power off and on again on the Handler. This will
force a communication handshake between the scales
and handler
Ensure autodrafting option on your indicator is selected
PARTS OF THE UNIT ARE WORKING SLOWLY
Constricted, broken or punctured air lines
Check the airlines for cracks & leaks
Remove hoses from the cylinder and test. This will
help identify if the issue is a air issue or a cylinder issue
Ensure the compressor is resting upon the airlines
CRUSH WALL IS NOT OPERATING QUICKLY ENOUGH
Low air pressure
Check the compressor–require 90--120 psi
TILT GOING BACK OR CREEPING OVER
Faulty switch
Faulty solenoid
Air leak
Repair or replace the switch
Replace solenoid
Check joints and lines and remedy as required
Remove air line and see if there is air flow leaking
through the valve. If so contact support
UNIT IS NOT CATCHING PROPERLY
Low air pressure
Eye not working
Dirty Sensor (eye)
Incorrect eye positions
Check compressor output is above 90 psi at all times
Check sensor (eye) and cables for damage
Remove wool and/or dust from the sensor (eye) lenses
Adjust positions so 1x blue and 1x black eye get covered
Remove air line and see if there is air flow leaking
through the valve. If so contact support
WALL PRESSURE IS HIGH ALL THE TIME
Faulty potentiometer
Check and adjust or replace as required
Remove hoses from ram and activate catch and see
if air keeps coming out should only do a short burst,
possible the valve needs service as its stuck open