RBK-X1C
PN 2376800-1
Page 36 Rev. A Dec. 2020
4.2.10
Heater Carriage Jammed
Heater Carriage Jams.
Power to the motor and heater will remove automatically.
The RBK processor heaters will switch off automatically if the carriage has not reached the front
sensor in 700ms. Power to the drive motor removed.
Heater
’s
cool down and the RBK Processor will go into Stand-by mode, exactly as if the operator were
preparing to switch the machine off.
The equipment is connected to an AC mains electricity supply. Before undertaking
any maintenance or repair, always turn off the equipment and ensure it is isolated
from the AC supply
Clear the jam. Check for signs of damage to Processor. Ref Emergency Heater Chamber
Release:
section 4.2.11
To reset the Processor:
1. Switch on the Processor by pressing the I/O switch for 5 seconds.
2. Press on both start button.
3. This will move the mechanism back and reset the fault condition.
4. Processor is now ready to use.