Page 25 Rev. A Dec. 2020
3.10
Error Log
This page will show error message on HMI. Other machine issue please find from section 4.3
Troubleshooting
Error
Possible Reason
Action
Power off!
The machine isn't powered off in right process
1. Emergency stop button be pushed
2. The power supply is cut
1. Check the emergency stop button was pressed
or not
2. Check the power supply of machine
Load position timeout!
1. Load position sensor error
2. The heating chamber be jammed
3.The motor error
1. Check load position sensor
2. Check the heating chamber be jammed or not
3. Check the motor
Home position
timeout!
1. Home position sensor error
2. The heating chamber be jammed
3.The motor error
1. Check home position sensor
2. Check the heating chamber be jammed or not
3. Check the motor
Standby time is up!
The time that operator doesn't operate the machine is
longer than the stan-by time, the machine is in standby
mode automatically
Press the IO button for 5s to power on the
machine
Failed to find home
position!
When power on the machine the heating chamber isn't on
home position, and push two hands buttons, the heating
chamber can't back to home position
1. Check home position sensor
2. Check the heating chamber be jammed or not
3. Check the motor
Emergency stop!
Emergency stop button be pushed
Release the emergency stop button
Setting temperature
too high!
Setting temperature value is higher than 675
℃
Reset the temperature value lower than 675
℃
Temperature error!
Actual temperature is higher than 675
℃
1. Check the temp sensor
2. Check the temp controller
Temp controller
comm error!
1. The communication cable between PLC and temp
controller is damaged
2. The PLC communication port is damaged
3. The temp controller error
1. Check the communication cable between PLC
and temp controller
2. Check the PLC communication port
3. Check the temp controller
Probe up/down alarm! 1.
Probe up/down sensor error
2.
Inner connection of CD cable fail
1.
Check the sensor
2.
Reconnect the cable from top front cover
HST left/right alarm! 1.
HST left/right sensor error.
2.
Outer connection of CD cable fail
1.
Check the sensor
2.
Reconnect the outer CD cable
Pull HST Disable!
1. Pull HST sensor error.
1. Check the sensor
Summary of Contents for RBK-X1C
Page 55: ...RBK X1C PN 2376800 1 Page 54 Rev A Dec 2020 6 Schematic Diagram...
Page 56: ...RBK X1C PN 2376800 1 Page 55 Rev A Dec 2020...
Page 57: ...RBK X1C PN 2376800 1 Page 56 Rev A Dec 2020...
Page 58: ...RBK X1C PN 2376800 1 Page 57 Rev A Dec 2020...
Page 59: ...RBK X1C PN 2376800 1 Page 58 Rev A Dec 2020...
Page 60: ...RBK X1C PN 2376800 1 Page 59 Rev A Dec 2020...
Page 61: ...RBK X1C PN 2376800 1 Page 60 Rev A Dec 2020...
Page 62: ...RBK X1C PN 2376800 1 Page 61 Rev A Dec 2020...
Page 63: ...RBK X1C PN 2376800 1 Page 62 Rev A Dec 2020...
Page 64: ...RBK X1C PN 2376800 1 Page 63 Rev A Dec 2020 7 Pneumatic Diagram...