114-94467
Rev. C
18
of 31
Step 4
Dismantle the wires and crimp the contacts: 0.35 mm² Signal Wires
Remove outer cable sheath, cut one of the 12 single wires right after the cable sheath and remove the single
wire insulation from the remaining 11 single wires acc.
and
Figure 20
Wire Size
Removal of insulation dim. "A"
Length of single wires dim.
“B”
0,35 mm²
Acc. spec. 114-13000
50 ± 2 mm
Table 5
Crimp the conductors to the CONTACT MICRO MNL 794606-1 acc. Spec. 114-13000.
Step 5
Push crimped CONTACT MICRO MNL 794606-1 into the 12P MICRO MNL HSG 1-794617-2 acc. spec 114-
13000. Correct pinning acc.
Figure 21