ATTENTION: The correct contact positions have to be ensured BEFORE pushing the contacts into their
cavities in locking position.
In case of wrong positioning of the contacts the complete assembly has to be scrapped. There is no
rework allowed (risk of damaging contacts and/or locking geometry in housing)!
ESD safety required
– The printed circuit boards are static sensitive devices, which can be damaged if
touched without the necessary electrostatic discharge (ESD) precautions.
Figure 32
Figure 33
Proposed sequence for contact insertion:
1) 16mm² PE contact
2) 6mm² AC Power contacts starting with L1 and continuing in clockwise order
3) 35mm² DC Power contact