114-94467
Rev. C
17
of 31
Figure 18
Wire
Size
Removal of insulation
dim. "A"
(valid for 4 single
wires)
Length of single
wires dim. “B”
(valid for 4 single
wires)
Removal of insulation
dim. "C”
(valid for 1 single
wire)
Length of single wire
dim. “D”
(valid for 1 single
wire)
6 mm²
13 ± 1 mm
60 ± 2 mm
acc. LEVC
70 + “x” ± 2 mm
Table 3
The value “x” for length “D” in above table represents the wire length outside the inlet and needs to be defined
by LEVC.
Crimp the conductors of the 4 short single wires to the PIN DIA6.0 POWER AC 2293269-3 with the specified
tools listed in
. The crimp must fulfil the requirements from
Chapter 5
Step 3
Dismantle the wire and crimp the contact: 16 mm² PE Cable
Remove outer insulation acc.
Figure 19
Wire Size
Removal of insulation dim. "A"
16 mm²
16 ± 1 mm
Table 4
Crimp conductor to the PIN DIA6.0 POWER PE 2293270-4 with the specified tools listed in
. The crimp
must fulfil the requirements from
Chapter 5