34
Section IV
– Pipeline Under Pressure
2.0 Continued
Figure 4.23.
Measurements “G”,
“J”, and “K”
✎
EXAMPLE
Setting a two-inch PIG-SIG V using a threaded
adapter and assuming Measurement “G” to be 2-5/8-
inch. The Measurement “J” is 4-1/2-inch:
Measurement “G” = 2-5/8”
Measurement “J” = 4-1/2”
Measurement “K” = 1-7/8”
TOTAL = 9”