AN-000240
Document Number: AN-000240
Page 12 of 23
Revision: 2.0
3.3.3 Settings: Tuning with Custom Parameters
To tune for custom apparatus, floor types, or different setups, custom parameters need to be used
Steps:
1.
Mount the module to the desired location with the horn/housing facing downward to the floor surface. The sensor must be
facing the floor surface with no tilt or reflective surroundings. For more information on module mounting, refer to
Section
2.
In the unpacked folder (RoboFloor_vX.X.X.exe) and in the GUI folder, open
‘Gui
-demo-robofloor-
x.x.x’
.
3.
Click the settings icon (
) to input settings.
4.
To use custom parameters, the “
Use Customer Configuration (Parameters Below)
” must be
checked. Edit values for each
setting (see Algo Setting Descriptions below). Load or save settings using the buttons. This will load or save a .json file from
the GUI folder.
Figure 3-5. Settings: Algo Settings
5.
Hit ‘OK’ to save settings for current run. Then click ‘Connect’ to display real
-time outputs.