100
7.12.5 Measure Subsystem
This subsystem reads the actual voltage and current. The power is a result of multiplying voltage
and current measurements.
MEASure
:CURRent[:DC]?
:VOLTage[:DC]?
:POWer[:DC]?
MEASure:CURR?
Reads the measured output current. Returns a 5 digit string.
SCPI Command Syntax
MEASure:CURRent?
GEN Command Syntax
MC?
Parameters
None
Default Suffix
A
Returned Parameters
<NR3>
MEASure:VOLTage?
Reads the measured output voltage. Returns a 5 digit string.
SCPI Command Syntax
MEASure:VOLTage?
GEN Command Syntax
MV?
Parameters
None
Default Suffix
V
Returned Parameters
<NR3>
MEASure:POWer?
Reads the measured output power. Returns a 5 digit string.
SCPI Command Syntax
MEASure:POWer?
GEN Command Syntax
MP?
Parameters
None
Default Suffix
W
Returned Parameters
<NR3>
7.12.6 DISPlay Subsystem
DISPlay
[:WINDow]:STATus <bool>
Display ON/OFF
[:WINDow]:FLASh <bool>
Display Flash