background image

43

4.3 Rear Panel Connectors

Refer to Fig.4-2 and Table 4-2 for description of the Rear Panel connectors.

No.

Connection

Description

Section

1

AC Input Connector

IEC320-16 TYPE CONNECTOR

2

DC output bus-bar

Bus-bars for 10V to 100V models. Use M6 or 1/4”  screws.

3.9.9

3

Analog Control and 

signals. J1

Connector for remote analog interface. Analog control and monitoring. 

Referenced internally to output potential -S.

4.3.1

4

Local/Remote sense 

connector J2

Connector for making remote sensing connections to the load for 

regulation of the load voltage and compensation of load wire drop.

3.8.1

3.10.2

5

Isolated control and 

signal. J3

Control and monitoring signal, isolated from the output potential.

4.3.2

6

Remote Serial Out 

connector

RJ-45 type connector, used for chaining power supplies to/from a serial 

communication bus.

7.3

7

Remote Serial In 

connector

RJ-45 type connector, use for connecting power supplies to RS232 or 

RS485 port of computer for remote control purposes. When using several 

power supplies in a power system,  the first unit Remote-In is connected 

to the computer and the remaining units are chained, Remote-In to 

Remote-Out.

7.3

8

USB Connector

USB interface connector, type B

9

LAN Connector 

(optional)

LAN interface connector, type RJ-45

10

Ground screw

M4x10 for chassis Ground connection

11

Optional Interface

Position for GPIB Interface (shown) or Isolated Analog Interface.

Table 4-2: Rear panels connecions

Fig. 4-2: Rear panel connections

Summary of Contents for Z+ series

Page 1: ...rammable DC Power Supplies 200W 400W 600W 800W in 2U Built in USB RS 232 RS 485 Interface Optional Interface LXI Compliant LAN IEEE488 2 SCPI GPIB Multi Drop Isolated Analog Programming Series User Ma...

Page 2: ...ER MANUAL Series This Manual Covers Models Z10 20 Z20 10 Z36 6 Z60 3 5 Z100 2 Z10 40 Z20 20 Z36 12 Z60 7 Z100 4 Programmable DC Power Supplies 200W 400W Built in USB RS 232 RS 485 Interface IA710 04 0...

Page 3: ...azardous substance included in a homogeneous part of a respective part or material exceeds the concentration limit regulated by SJ T 11363 2006 Requirements for Concentration Limits for Certain Hazard...

Page 4: ......

Page 5: ......

Page 6: ...ICATIONS 2 1 Z 200 SERIES SPECIFICATIONS 19 2 2 Z 400 SERIES SPECIFICATIONS 22 2 3 Supplemental Characteristics 25 2 4 Z200W 400W Outline Drawing 26 2 5 Z200W 400W Optional IEEE Isolated Analog Interf...

Page 7: ...es 47 4 5 Navigating the Main Menu 48 4 5 1 Introduction 48 4 5 2 Exiting the Main Menu 48 4 6 Navigating Communication Menu 49 4 6 1 Introduction 49 4 6 2 Exiting the Communication Menu 50 4 7 Naviga...

Page 8: ...n 1 and Pin 2 64 5 7 4 Power Supply OK Signal 65 5 8 Rear Panel J1 Connector Functions 65 5 8 1 CV CC Signal 65 5 9 Parameter Setting Memory 66 5 9 1 Default Setting 66 5 9 2 Reset 66 5 9 3 Last Setti...

Page 9: ...nts 86 7 10 6 SCPI Command Hierarchy 86 7 10 7 Header 86 7 10 8 Data Formats 87 7 10 9 Character Data 87 7 10 10 Commands Notes 87 7 11 SCPI Common Commands 87 7 12 SCPI Subsystem Commands 92 7 12 1 O...

Page 10: ...tus Byte Register 122 9 6 4 Determining the Cause of a Service Interrupt 122 9 6 5 Output Queue 123 9 6 6 Error Messages 123 CHAPTER 10 ISOLATED ANALOG PROGRAMMING OPTION 10 1 Introduction 125 10 2 Sp...

Page 11: ...ny damage occurring as a result of the buyer s circuitry or the buyer s supplied products No other warranty is expressed or implied Warranty Service This product must be returned to an authorized TDK...

Page 12: ...easurement Control and Laboratory Use Part 1 General Requirements A Declaration of Conformity in accordance with the preceding directives and standards has been made and is on file at our EU represent...

Page 13: ...thegroundwirefirmlyconnected to an electrical ground safety ground at the power outlet Any interruption of the protective ground conductor or disconnection of the protective earth terminal will cause...

Page 14: ...der gef hrlichen Energiestufe d rfen der Ausgang und die Verbindungen nicht f r Benutzer zug nglich sein Die Endger te des Herstellers m ssen den Schutz des Bedienungspersonals gegen versehentlichen K...

Page 15: ...len Nichteinhaltung desVerfahrenskannzuK rperverletzungf hren EinWARN Hinweisdarfnichtignoriert und alle angef hrtenVerfahren m ssen eindeutig verstanden und umgesetzt werden Denotes hazard An attenti...

Page 16: ...gnalsorbythebuilt in serial communicationUSB and RS232 485 LAN IEEE and Isolated Analog programming monitoring are optional 1 2 2 Models Covered by this Manual Model Voltage range V Current range A Z1...

Page 17: ...an be programmed by analog voltage or by resistor and can be monitored by analog voltage The power supply output can be remotely set to On or Off and analog signals monitor the proper operation of the...

Page 18: ...d it should be ordered according to the following Part no Market Description Z U USA 13A 125V non shielded 2m typical length with IEC60320 1 type C15 connector on one end and NEMA 5 15P type plug on t...

Page 19: ...10 20 20 10 36 6 60 3 5 100 2 1 Max Line regulation 6 0 01 of rated output current 2mA 2 Max Load regulation 11 0 01 of rated output current 5mA 3 Load regulation thermal drift Less than 0 05 of rate...

Page 20: ...imum source current 8mA pulse 20us Typical 16 Trigger in Maximum low level input voltage 0 8V minimum high level input votage 2 0V Maximum sink current 8mA possitive edge trigger tw 10us minimum Tr Tf...

Page 21: ...LAN are Non Hazardous EMC IEC61326 1 Built to meet EN55022 EN55024 2 Withstand voltage 10 Vout 36V models Input Output J1 J2 J3 J4 USB LAN IEEE ISOLATED ANALOG 4242VDC 1min Input Ground 2828VDC 1min O...

Page 22: ...age change equal to the unit voltage rating constant input voltage 12 For 10V model the ripple is measured at 2V to rated output voltage and rated output current For other models the ripple is measure...

Page 23: ...6 12 60 7 100 4 1 Max Line regulation 6 0 01 of rated output current 2mA 2 Max Load regulation 11 0 01 of rated output current 5mA 3 Load regulation thermal drift Less than 0 05 of rated output curren...

Page 24: ...mum source current 8mA pulse 20us Typical 16 Trigger in Maximum low level input voltage 0 8V minimum high level input votage 2 0V Maximum sink current 8mA possitive edge trigger tw 10us minimum Tr Tf...

Page 25: ...Non Hazardous EMC IEC61326 1 Built to meet EN55022 EN55024 2 Withstand voltage 10 Vout 36V models Input Output J1 J2 J3 J4 USB LAN IEEE ISOLATED ANALOG 4242VDC 1min Input Ground 2828VDC 1min Output J1...

Page 26: ...2mSec 6 At 85 132Vac or 170 265VAC constant load 7 From No Load to Full Load constant input voltage Measured at the sensing point in Remote Sense 8 Measured with JEITA RC 9131A 1 1 probe 9 From 10 to...

Page 27: ...26 2 4 Z200W 400W Outline Drawing...

Page 28: ...27 2 5 Z200W 400W Optional IEEE Isolated Analog Interface Outline Drawing...

Page 29: ...28 2 6 Z200W 400W Front Panel Output Binding Post Outline Drawing...

Page 30: ...r supply Ensuring adequate ventilation Section 3 4 Section 3 5 3 AC source AC source requirements Connecting the power supply to the AC source Section 3 6 Section 3 7 4 Test Turn on checkout procedure...

Page 31: ...at under heavy load the AC voltage supplied to the power supply does not fall below the specifications described in Chapter 2 Netzstromanforderungen DieGer tederZ Seriek nnenauseinemeinphasigenNetzstr...

Page 32: ...o section 1 3 4 for details of the AC input cords recommended WARNING The AC input cord plug is the disconnect device of the power supply The plug must be readily identifiable and accessible to the us...

Page 33: ...of the CURRENT display Ensure that the front panel CURRENT LED is on 5 Turn off the front panel AC power switch 6 Remove the shunt from the power supply output terminals 3 8 5 OVP Check RefertoSectio...

Page 34: ...ock hazard when using a power supply with a rated output greater than 70V WARNING Thereisapotentialshockhazardwhenusingapowersupplywitharatedoutputvoltagegreaterthan 42 4V Turn off the AC input power...

Page 35: ...and 3 3 use the formula Maximum length 1000 current x resistivity Where current is expressed in amperes and resistivity in ohms km or ohms 1000ft 3 9 2 Current Carrying Capacity Two factors must be c...

Page 36: ...ve loads can produce voltage spikes that may be harmful to the power supply A diode should be connected across the output The diode voltage and current rating should be greater than the power supply m...

Page 37: ...There is a potential shock hazard when using a power supply with an output voltage greater than 42 4V Do not turn ON power supply an output voltage above 42 4VDC without output bus bars or output conn...

Page 38: ...mportant at the load terminals Use twisted or shielded wires to minimize noise pick up If shielded wires are used the shield should be connected to the ground at one point either at the power supply c...

Page 39: ...und it is recommended to ground the output terminal as close as possible to the power supply chassis ground Always use two wires to connect the load to the power supply regardless of how the system is...

Page 40: ...an output voltage greater than 42 4V Local sense and remote sense wires should have a minimum insulation rating equivalent or greater than the maximum output voltage of the power supply Ensure that th...

Page 41: ...plugged securely into the rear panel sense connector J2 4 Turn On the power supply NOTES 1 If the power supply is operating in remote sense and either the positive or negative load wire is not connec...

Page 42: ...Before starting to operate the unit please read the following sections for an explanation of the functions controls and connector terminals Section 4 2 Front Panel Display and Controls Section 4 3 Rea...

Page 43: ...ocal Lockout mode Green LED lights when the unit is in communication Remote mode Auxiliary function Communication menu 10 PREV button indicator Main function Press PREV to display the output voltage a...

Page 44: ...J3 Control and monitoring signal isolated from the output potential 4 3 2 6 Remote Serial Out connector RJ 45 type connector used for chaining power supplies to from a serial communication bus 7 3 7 R...

Page 45: ...ndloopsandtomaintaintheisolationofthepowersupplywhenprogrammingfrom J1 use an ungrounded programming source WARNING There is a potential shock hazard at the output when using a power supply with outpu...

Page 46: ...f the Output Voltage 6 4 6 5 7 COM Control Common Return for VMON IMON CV CC LOC REM Connected internally to the negative sense potential S 8 CV CC Output for Constant Voltage Constant Current mode in...

Page 47: ...nal name Function Section 1 Programmed Signal 1 General Purpose Open collector Port 1 5 7 3 2 PS_OK Output for indication of the power supply status High level is OK 5 7 4 3 Trigger Out Trigger output...

Page 48: ...ECT DELAY ENA ENABLE RANG RANGE ERES EXT RESISTOR R PAN REAL PANEL Err ERROR RECL RECALL euOL EXT VOLTAGE RST RESET ext EXTERNAL SAFE SAFESTART F rSt FACTORY RESET SAuE SAVE FAIL FAIL SCPI SCPI FOLD F...

Page 49: ...hows the function and the Current display shows the parameter Scroll the parameter list by rotating the Current Encoder and press to select the desired parameter When parameter is accepted the display...

Page 50: ...play Navigate by rotating theVoltage Encoder to scroll the function level Toselectthedesiredfunction presstheEncoderbuttonnexttothedisplay IntheParameter level theVoltage display shows the function an...

Page 51: ...P functions In the Parameter level the Voltage display shows the function and the Current display shows the parameter Scroll the parameter list by rotating the Current Encoder Selection of a numerical...

Page 52: ...odertorequiredvalue TheVoltagedisplaywillshow the programmedoutputvoltagefor5seconds Then OFF willappearonthe Voltagedisplay 4 Resolution can be set to Coarse or Fine adjustment Press FINE button to s...

Page 53: ...ing of Output Voltage and Current limit with the output enabled Auto restart or it can start with the output disabled Safe mode Press and hold the OUT button to toggle between Safe start and Auto rest...

Page 54: ...of a remote or local programming error or a power supply failure The protection circuit monitors the voltage at the power supply sense points thus providingtheprotectionlevelattheload Upondetectionofa...

Page 55: ...VL can be set when the power supply output is Enabled On or Disabled Off UVL and UVP setting values are limited at the maximum level to approximately 5 below the Output Voltage setting Attempting to a...

Page 56: ...ncoder 3 The message appears on the Voltage Display The Current display shows the value in seconds 4 Rotate the Current Encoder to adjust the delay Protection delay setting range is 0 25 5sec 5 Press...

Page 57: ...with local and remote sensing S S LS LS S S LS LS S S LS LS S S LS LS POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY LOAD LOAD Diodes are user supplied Fig 5 1 Series connection local sensing Fi...

Page 58: ...ced to the isolated interface common IF_COM J3 7 The IF_COM terminals of the units can be connected to obtain a single control circuit for the power supplies connected in series Programming by externa...

Page 59: ...peration In this method setting the units as Master and Slaves is made by the rear panel J1 connections and setup via Front Panel Each unit displays its own output current and voltage To program the l...

Page 60: ...lay blinks once and returns to previous display 5 For wiring instructions refer to Fig 5 4 Parallel connection with local sensing or Fig 5 5 Parallel connection with remote sensing 5 5 2 3 Setting Ove...

Page 61: ...onnection may cause damage to the power supply NOTE With local sensing it is important to minimize the wire length and resistance Also the positive and negative wire resistance should be as close as p...

Page 62: ...nce and returns to previous level Refer to Table 5 2 1 4 Recycle AC power 5 5 3 2 Setting Up of Slave Units When Advanced Slave mode is selected the power supply enters Current programming mode via ex...

Page 63: ...illrecovertotheirlastsettingaccordingtotheirrespectiveSafestartorAuto restartsetting Fig 5 6showsconnectionofthreeunits howeverthesameconnectionmethodappliestosystems with more units Fig 5 6 Daisy Cha...

Page 64: ...ears on the Current display 2 Press Current Encoder The message appears on the Current display 3 PresstheCurrentEncoderagain The messageappearsontheVoltagedisplay Parameter or G appears on the Current...

Page 65: ...ollector maximum input voltage 25V and maximum sink current 100mA and can be controlled via Front panel or software Pin 1 or Pin 2 settings are made as follows 1 Press MENU button MENU GREEN LED illum...

Page 66: ...Voltage Encoder until message appears and press Encoder 4 Parameter delay time in mSec appears on the Current display 5 RotatetheCurrentEncodertoadjustthesettinglevel PS_OKdelayrangeisfrom0 9999mSec 6...

Page 67: ...Encoder Message appears on the display for 1sec The display blinks once and returns to previous level 7 Press MENU button twice to return display to previous state MENU LED turns OFF NOTE Noresponsef...

Page 68: ...ent Encoder to select required number value and then press the Current Encoder Display blinks and returns to previous level 5 9 5 Recall 1 4 This command recalls the present state of the power supply...

Page 69: ...Delay 0mS 0mS Voltage Programming Mode Digital Current Programming Mode Digital Programming and Monitor Range 5V Current Share Mode Master Slave Master H1 Interlock PROTote Inhibit OFF disabled OFF d...

Page 70: ...item 1 accepts TTL signal or Open Short contact Referenced to J1 7 9 to select between Local or Remote Analog programming of the output voltage and current limit In Local mode the output voltage and c...

Page 71: ...Current 6 The selected function appears on the Voltage display Parameter F Pan or E uOL or E res appears on the Current display 7 Rotate and press the Current Encoder to select E uOL 8 uOLt message ap...

Page 72: ...nates Set messageappearsonVoltagedisplay 4 Press Voltage Encoder uOLt message appears on Voltage Display and CURR appears on the current display 5 Press on the Voltage Encoder to select programming th...

Page 73: ...6 Front panel PREV button Use PREV button to display the output voltage and current settings defined by the Encoders or Communication 6 6 Programming Monitoring of Output Voltage V_MON and Current I_...

Page 74: ...tween 1 and 31 1 Press REM button The REM LED illuminates message appears on the Current display 2 PressCurrentEncoder Voltagedisplayshows andCurrentdisplayshowspresentaddress 3 Rotate the Current Enc...

Page 75: ...eturns to the previous level 7 2 6 Setting Unit in Remote Local Lockout or Local Mode Local mode When the power supply is in local mode it can receive queries If a query is received the power supply w...

Page 76: ...5 RXD 4 TXD 3 NC 2 SG 1 IN OUT Shield Connector enclosure Fig 7 1 J4 rear panel IN OUT connectors pinout 7 3 Rear Panel RS232 485 Connector The RS232 485 interface is accessible through the Rear panel...

Page 77: ...X 8 RX PAIR 5 SG 1 SG Fig 7 3 RS232 cable with DB9 connector P N Z 232 9 D08 9 CONNECTOR 8 PIN CONNECTOR REMARKS PIN NO NAME PIN NO NAME HOUSING SHIELD HOUSING SHIELD 9 TXD 6 RXD TWISTED 8 TXD 3 RXD P...

Page 78: ...to the USB port on the computer 2 Insert the software CD ROM that is shipped with the product to your CD ROM Drive The Z drivers selection menu will automatically appears click on the ICON USB drivers...

Page 79: ...ed commands by returning OK message If an error is detected the power supply will return an error message The rules for checksum also apply to the acknowledge feature 7 7 6 Backspace The backspace cha...

Page 80: ...Set Description 7 8 1 General guides 1 Any command or argument may be in capital letters or small letters 2 In commands with an argument a space must appear between the command and the argument 3 For...

Page 81: ...string of ASCII characters A comma will separate the different fields The fields in order are Measured Voltage Programmed Voltage Measured Current Programmed Current Over Voltage Set point and Under V...

Page 82: ...s OVP level to the maximum level Refer to Table 7 8 UVL n Sets Under Voltage Limit Maximum value of n is 5 below PV setting but returns E06 if higher Refer to Table 7 9 for UVL programming range UVL R...

Page 83: ...tput cannot be turned on because of a latching fault OTP AC ENA SO shutdown GSAV Save present settings Same settings as power down last settings listed in Error Reference source not found Except the a...

Page 84: ...tisnotrecommended to program the power supply over the rated values NOTE The UVP protection starts operating for values higher than 5 of Rated Output Voltage 7 8 7 Auxiliary Commands SOP Sets SO polar...

Page 85: ...hex Example response MV 45 201 PV 45 MC 4 3257 PC 10 SR 0030 FR 0000 2 FLT Reads Fault Conditional Register Return 4 digit hex 3 FENA Set Fault Enable Register using 4 digit hex 4 FENA Reads Fault Ena...

Page 86: ...3 Power supply set up 3 1 Connect the power supply to the PC using the RS232 cable 3 2 Set via the front panel Baud Rate 9600 Address 06 RS232 GEN Language 4 Communication test 4 1 Model identificatio...

Page 87: ...s 14 Boolean data 1 0 or ON OFF 7 10 6 SCPI Command Hierarchy SCPIisanASCII basedcommandlanguagedesignedforuseintestandmeasurementequipment The command structure is organized around common roots or no...

Page 88: ...re optional and entered without the or Expressions enclosed in greater than less than are programming values and entered without the or The expression SP represents a one character ASCII Space In all...

Page 89: ...y error ESR Standard Event Status Register query Returns the contents of the Event Status Register Meaning andType Event Status Device Status Query Syntax ESR Parameters None Returned Parameters NR1 R...

Page 90: ...list of all of the instrument options currently installed on the signal generator Parameter Option 0 NONE 1 IEEE 2 LAN 3 BOTH Query Syntax OPT Returned Parameters CRD PSC The Power On Status Clear PS...

Page 91: ...mmand Meaning andType Recall Device State Command Syntax RST Parameters None Example None SAV n The SAV command saves all applied configuration setting Refer to Table 5 7 Command Syntax SAV NRf Parame...

Page 92: ...Master status summary OPER Operation status summary QUES Questionable status summary RQS Request for service Table 7 10 Bit Configuration of Status Byte Register TRG The Trigger command starts the wa...

Page 93: ...e in Safe or Auto start PROTection CLEar Reset latched protection FOLDback MODE CRD Protection at transition CC CV modes DELay NRf Delay after programming before protection ILC MODE CRD Set remote inh...

Page 94: ...conditions that generate a fault must be removed before the latch can be cleared The output is then restored to the state before the fault condition occurred SCPI Command Syntax OUTPut PROTection CLEa...

Page 95: ...UTPut ILC MODE ON Query Syntax OUTPut ILC MODE Returned Parameters ON OFF OUTPut TTLTrg MODE Sets the operation of the Trigger Out signal to either OFF Function Strobe or Trigger mode Programming Mode...

Page 96: ...or CC When the power supply is OFF OUT 0 it will return to OFF SCPI Query Syntax OUTPut MODE GEN Query Syntax MODE Returned Parameters CRD CV CC OFF 7 12 2 Instrument Subsystem The subsystem programs...

Page 97: ...AMPLitude NRf GEN Command Syntax PV NRf PV Default Suffix V RST Value 0 Examples VOLT 500 MV VOLT LEV 234 56789 Query Syntax SOURce VOLTage LEVel IMMediate AMPLitude VOLTage MAX VOLTage MIN Returned...

Page 98: ...ix V RST Value MAX Examples VOLT PROT LEV 2 5 Query Syntax SOURce VOLTage PROT LEV VOLT PROT LEVel MIN VOLT PROT LEVel MAX Returned Parameters NR3 VOLT PROT LEV returns presently programmed OVP level...

Page 99: ...y Thependingtriggeredvoltage level is a stored value that is transferred to the output terminals when a trigger occurs SCPI Command Syntax SOURce VOLTage LEVel TRIGgered AMPLitude NRf GEN Command Synt...

Page 100: ...Value NONE Examples CURR MODE LIST CURR MODE FIX Query Syntax SOURce CURRent MODE Returned Parameters NONE FIX LIST WAVE CURRent TRIGger Programs the pending triggered current level of the power supp...

Page 101: ...eters None Default Suffix A Returned Parameters NR3 MEASure VOLTage Reads the measured output voltage Returns a 5 digit string SCPI Command Syntax MEASure VOLTage GEN Command Syntax MV Parameters None...

Page 102: ...t panel voltage and current displays flash SCPI Command Syntax DISPlay WINDow FLASh bool GEN Command Syntax none Parameters 0 OFF 1 ON Examples DISP FLASh 1 DISP FLASh OFF Query Syntax DISP FLASh Retu...

Page 103: ...7 12 8 LIST Subsystem SOURce LIST COUN NRf CURR NRf LOAD NR1 STEP STORe NR1 DWELl NRf VOLT NRf This subsystem receives parameters to create a step waveform of the output voltage or current NOTE All li...

Page 104: ...cifies the time interval that each value point of a list is to remain in effect SCPI Command Syntax SOURce LIST DWEL NRf NRf Range 0 01 to 65 MINimum MAXimum Default Suffix S Examples LIST DWEL 6 1 5...

Page 105: ...1 for more details STATus OPERation Returns the value of the Event register EVENt Returns the value of the Condition register CONDition Set current value for Trigger pending ENABle NR1 Enables specif...

Page 106: ...r Value decimal Default Value 0 Query Syntax STATus OPERation ENABle Examples STAT OPER ENAB 1312 STAT OPER ENAB 1 STATus QUEStionable EVENt This query returns the value of the Event register It is a...

Page 107: ...nable Error Message ERRor Read system error Error Messages LANGuage REMote STATe Set program mode 0 LOC Local 1 REM Remote 2 LLO Go to Lockout VERSion Software revision DATE Calibration Date PON TIME...

Page 108: ...T 1 LLO 2 RST Value LOC Examples SYST REM RMT Query Syntax SYST REM Returned Parameters LOC RMT LLO SYSTem VERSion SCPI Command Syntax SYSTem VERSion CRD GEN Command Syntax REV Parameters Rev 1 0 1 0...

Page 109: ...me delay between the detection of an event on the specified trigger source and the start of any corresponding trigger action on the power supply output SCPI Command Syntax TRIGger STARt DELay NRf GEN...

Page 110: ...NFinity RST 1 Examples WAVE COUN 3 WAVE COUN INF Query Syntax SOURce WAVE COUNt if count 9999 the response is INF Returned Parameters NR3 WAVE CURR This command specifies the output current points in...

Page 111: ...ory defined by numbers 1 4 SCPI Command Syntax SOURce WAVE STORe NF1 Examples WAVE STORe 3 WAVE TIME Sets the slope time of the waveform SCPI Command Syntax SOURce WAVE TIME NRf1 NRf1 Range 0 01 to 65...

Page 112: ...d can be issued Global Commands List Command Name Description SCPI Format GEN Format Result From Supply Enable all Outputs Output On to last V I levels GLOBal OUTPut STATe 1 ON GOUT 1 None Disable all...

Page 113: ...trigger refer to section 8 5 1 According to the selected mode the power supply activates the output trigger on J3 3 refer to section 8 5 2 8 2 FIX Mode Output value is changed via input trigger Refer...

Page 114: ...p Started DWELL LIST DWELL 0 05 0 06 0 03 STC Step Complited OPC Operation Complited OUTPUT LIST VOLT 5 10 0 VOLTAGE 0 02s 0 05s 0 06s 0 03s LIST STEP AUTO 8 3 LIST Mode Output change value in step de...

Page 115: ...Started TIME 0 03s 0 02s 0 03s WAVE TIME 0 3 2 3 STC Step Complited OPC Operation Complited WAVE VOLT 5 10 10 0 OUTPUT VOLTAGE WAVE COUN 2 INIT CONT 0 WAVE MODE AUTO 0 02s 0 03s 0 02s 0 03s 8 4 WAVE M...

Page 116: ...odes LIST or WAVE OFF No Trigger out In TRIG mode trigger is generated when LIST or WAVE is completed InFunctionStrobemode anoutputpulseisgeneratedautomaticallyanytimeastepiscompeted Output Trigger mo...

Page 117: ...rigger If 0 then send INIT command MENU G to get to the next trigger 4 Set INIT command Power supply ready for TRIGGER MENU G 5 Exit from MENU and Press Current Encoder to trigger 8 7 Additional Examp...

Page 118: ...LT MODE Trigger G Function Strobe Programming G LOAD List or Wave data L1 L4 Refertocommands LIST LOAD and WAVE LOAD COUNter set repeat time 1 9999 Refer to LIST COUN and WAVE COUN allow course and fi...

Page 119: ...hannel DWE 0 0 List Step Active 0 0 0 Reserved OR MSB M E S S A G E Output Queue LSB MSB STAT QUES COND FLT STAT QUES ENAB nnnn STAT QUES ENAB FENA nnnn FENA STAT QUES EVEN FEVE Condition Enable Event...

Page 120: ...et to show a fault or if an operating mode is active The bits are cleared when the fault or mode is cleared The registers are read only 9 3 1 Fault Register The fault register sets a bit when a Fault...

Page 121: ...sters 9 4 1 Conditional Registers The condition registers show a snapshot of the power supply state at the present time Some faults or mode changes occur and clear quickly before the control computer...

Page 122: ...C 1 ESR reads the Standard Event Status Event register Reading the register clears it Bit Signal Meaning 0 OPC Operation complete 2 QYE Query error 3 DDE Device dependent error 4 EXE Execution 6 CME C...

Page 123: ...atches RQS into bit 6 of the Status Byte register When the controller services the interrupt RQS is cleared inside the register and returned in bit position 6 of the response The remaining bits of the...

Page 124: ...follows Bit Set Error code Error Type Bit Set Error code Error type 5 100 thru 199 Command 3 300 thru 399 Device dependent 4 200 thru 299 Execution 2 400 thru 499 Query Table 9 5 Standard Event Statu...

Page 125: ...UVL Setting 304 OVP Below PV Attempt To Set OVP Below Voltage Setting 305 UVL Below Zero Attempt To Set UVL Above Voltage Setting 306 UVL Above PV Attempt To Set UVL Above Voltage Setting 307 On Duri...

Page 126: ...nt PPM C 100 Output current programming temperature coefficient PPM C 100 Input impedance Ohm 1M Absolute maximum voltage Vdc 0 15 Max voltage between program inputs and supply outputs Vdc 600 Monitor...

Page 127: ...ogramming input 0 5 0 10V 4 20mA 3 IPROG_ISO Output current programming input 0 5 0 10V 4 20mA 4 GND Ground for programming signals Ground Ground 5 GND Ground for programming signals Ground Ground 6 V...

Page 128: ...age display Parameter F Pan or E uOL or E res appears on the Current display 7 Rotate and press the Current Encoder to select E uOL 10 uOLt message appears on Voltage Display and CURR appears on the C...

Page 129: ...pressure compressed air to blow dust from the unit 11 4 Adjustments and Calibration No internal adjustment or calibration is required There is NO REASON to open the power supply cover 11 5 Parts Repla...

Page 130: ...d and sense wire connections for noise and impedance effects Minimize the drop on the load wires 3 9 4 3 9 8 No output Display indicates OUP Over Voltage Protection circuit is tripped Turn off the AC...

Page 131: ...rch den Hersteller oder autorisierte Servicestellen durchgef hrt werden d rfen enth lt das Handbuch keine Schaltpl ne Im Falle eines Defektes oder ungew hnlichem Verhalten des Ger tes setzen Sie sich...

Page 132: ...stantspannungs Modus Strombegrenzung und Spannungseinstellungen pr fen 5 2 Die Ausgangsspannung hat eine hohe Restwelligkeit Werden die Sense Anschl sse benutzt Ist der Spannungsfall ber die Lastleitu...

Page 133: ...ist mode 108 communication 15 44 68 80 local operation 46 U constant current 27 46 local sensing 26 34 UVL 27 49 constant voltage 27 46 UVP 49 cooling 15 25 M USB 68 72 maintenance 123 D Master Slave...

Page 134: ...NOTES...

Page 135: ...NOTES...

Page 136: ...NOTES...

Page 137: ...NOTES...

Page 138: ...1 www tdk lambda co il E mail info tdk lambda co il JAPAN TDK Lambda Corporation International Sales Divison Nittetsu Bldg 6F 1 13 1 Nihonbashi Chuo ku Tokyo 103 0027 Japan Tel 81 3 5201 7175 Fax 81 3...

Reviews: