52
5.2.3 Automatic Crossover
When the power supply operates in Constant Voltage mode, while the load current is increased
to greater than the current limit setting, the power supply will automatically switch to Constant
Current mode. If the load is decreased to less than the current limit setting, the power supply will
automatically switch back to Constant Voltage mode.
5.2.4 Output On/Off Control
The Output On/Off enables or disables the power supply output. The Output On/Off can be
activated from the front panel using the OUT button or from the communication interface. The OUT
button can be pressed at any time (except in Front Panel Lock mode or when a Fault condition
exists). When the output is disabled, the output voltage and current fall to zero and the Voltage
display shows “
OFF
”. Press the OUT button to recover from Faults such as: OVP, UVP and FOLD
faults, after the Fault conditions have been removed.
5.2.5 Safe Start and Auto-Restart Modes
At turn on, the power supply AC On/Off can start at last setting of Output Voltage and Current
limit with the output enabled (Auto-restart), or it can start with the output disabled (Safe
mode). Press and hold the OUT button to toggle between Safe start and Auto-restart modes. The
VOLTAGE display will continuously cycle between “
SAFE
” and “
ATO
” every 3 seconds. Releasing
OUT push button while one of the modes is displayed, selects that mode. The default setting at
shipment is in Safe mode.
•
Automatic Start Mode (
ATO
)
The power supply is restored to last operation setting. Upon start-up, the output is enabled
or disabled according to the last setting.
•
Safe Start Mode (
SAFE
)
The power supply is restored to last operation setting and sets the Output to Off state. At
start-up, the output is disabled and the output voltage and current are zero. To enable the
output, momentarily press OUT button.
5.2.6 Viewing Software Revision
Via the Front Panel Menu, it is possible view installed software revision.
1. Press MENU button. MENU (GREEN) LED illuminates. “
et
“ message appears on the Voltage
display.
2. Rotate Voltage Encoder until “
io
“ message appears on Voltage Display.
3. Press Voltage Encoder. The “
Re
“ message appears on the display, and the installed software
revision number appears on the Current display.
Summary of Contents for Z+ series
Page 4: ......
Page 5: ......
Page 27: ...26 2 4 Z200W 400W Outline Drawing...
Page 28: ...27 2 5 Z200W 400W Optional IEEE Isolated Analog Interface Outline Drawing...
Page 29: ...28 2 6 Z200W 400W Front Panel Output Binding Post Outline Drawing...
Page 134: ...NOTES...
Page 135: ...NOTES...
Page 136: ...NOTES...
Page 137: ...NOTES...