83
Model Rated Output
Voltage (V)
Minimum (V) Maximum (V)
10
0.5
12.0
20
1.0
24.0
36
2.0
40.0
60
5.0
66.0
100
5.0
110
Table 7-8: OVP programming range
Model Rated Output
Voltage (V)
Minimum (V) Maximum (V)
10
0
9.5
20
0
19.0
36
0
34.2
60
0
57.0
100
0
95.0
Table 7-9: UVL/UVP programming range
Model
Minimum (A)
Maximum (A)
10-20
00.00
20.00
20-10
00.00
10.00
36-6
0.000
6.000
60-3.5
0.000
3.500
100-2
0.000
2.000
Table 7-6: Z200 models Current programming range
Model
Minimum (A)
Maximum (A)
10-40
00.00
40.00
20-20
00.00
20.00
36-12
00.00
12.00
60-7
0.000
7.000
100-4
0.000
4.000
Table 7-7: Z400 models Current programming range
NOTE:
The power supply can accept values higher by 5% than the table values, however it is not recommended
to program the power supply over the rated values.
NOTE:
The UVP protection starts operating for values higher than 5% of Rated Output Voltage.
7.8.7 Auxiliary Commands
SOP
Sets SO polarity “SO 1/ON” –Positive (default), “SO 0/OFF”-Negative
SOP?
Returns the SO polarity
RIE
Remote inhibit (Interlock) enable. “RIE 1/ON”-Enable, “RIE 0/OFF”-Disable”
RIE?
Returns the RIE polarity. “ON” –interlock enable, “OFF”-interlock disable.
FRST
Factory reset command. This command cover *RST command and additional settings. Sets factory
default. This command breaks communication. Refer to Table
5-7.
MP?
Reads the actual output power. Returns 5 digit string.
REL1
Set auxiliary programmed pin state J3-1. “REL1 1/ON”- High, REL1 0/OFF”- Low
REL1?
Response auxiliary programmed pin state J3-1.
REL2
Set auxiliary programmed pin state J3-6, “REL2 1/ON”- High, REL2 0/OFF”- Low
REL2?
Response auxiliary programmed pin state J3-6
Summary of Contents for Z+ series
Page 4: ......
Page 5: ......
Page 27: ...26 2 4 Z200W 400W Outline Drawing...
Page 28: ...27 2 5 Z200W 400W Optional IEEE Isolated Analog Interface Outline Drawing...
Page 29: ...28 2 6 Z200W 400W Front Panel Output Binding Post Outline Drawing...
Page 134: ...NOTES...
Page 135: ...NOTES...
Page 136: ...NOTES...
Page 137: ...NOTES...