Page 13 of 20
17130 issue 31, June 2014
Alpha 600 Handbook
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
Temperature
0 to 50°C (derating 2.5%°C above 50°C to 65°C -
Not covered by approvals).
-40°C to +85°C
Humidity
5 to 95% RH non-condensing.
5% to 95% RH non-
condensing
Altitude
-200m to 3000m
-200m to 5000m.
Pressure
70kPa to 106kPa
54kpa to 106kpa
Orientation
Horizontal, on either side or vertical with
airflow upwards.
All
Material Group
IIIb
Pollution Degree
2
Overvoltage Category
II
Class
I
Weight
2.4 Kg (Dependent on configuration)
IP Rating
IPX0
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth - 2.25 - 2.35kVDC
Primary mains circuits to transformer core - 4.25 - 4.35kVDC*
Primary mains circuits to secondary -4.25 - 4.35kVDC*
Outputs to each other and to earth are isolated to 500VDC
*This test is not possible with modules fi tted to the unit as damage to RFI capacitors will occur).
Safety Approvals:
UL60950-1 and CSA22.2 No 60950-1-UL recognised.C-UL for Canada.
IEC/EN60950-1 - CE mark. CE marking when applied to any Alpha 600 product, indicates compliance with the Low
Voltage Dircetive (2006/95/EC) in that it complies with EN60950-1, and with Directive 2011/65/EU of the European
Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment.
Fusing:
Internal fuse (FS101) 6.3 x 32mm, F12AH/250V
Symbols:
AC
DC
EARTH
N – Neutral
L – Live
PRODUCTS COVERED
Unit Configuration Code:
Alpha 600, Alpha 600W and CA600 are identical.
(may be prefixed by NS - # / or - where # may be up to any four letters and may be followed by - $; where $
may be any number between 000 to 999, indicating non-safety related model differences.)
Alpha 600 or CA600 may be followed by: TL, RL, LL, ML, A or no letter,
where TL = Tiny leakage input filter
RL = Reduced leakage input filter
LL = Low leakage input filter
ML = Medium leakage input filter
A = Class A input filter
No letter = Class B input filter