MODE?
Operating Mode
Description
This query returns the load’s operating mode. The response is either
numeric or a text description depending on the TEXT ON/OFF and
STATXT ON/OFF settings. The returned value will be the sum of the
individual bit weights of the mode plus any mode modifiers. The
individual bits are defined below.
Mode Modifiers
Bit
Weight
Description
Text On
Response Message
8
256
Pulsing
PULSING
7
128
External Modulation
EXT MOD
Operating Modes
Bit
Weight
Description
Text On
Response Message
6
64
Slave Mode
SLAVE
5
32
Not Used
4
16
Not Used
3
8
Constant Resistance High
CR HIGH
2
4
Constant Resistance Low
CR LOW
1
2
Constant Power
CP
0
1
Constant Voltage
CV
Default
Constant Current
CI
The text response will return a string containing the Text On
Response Message as listed above for each bit that is set. These will
be separated by commas.
Command Syntax
NONE
Example
N/A
Query Syntax
MODE?
Returned Parameters
TEXT ON and STATXT ON: <text response string>
TEXT OFF or STATXT OFF: <NR1>
MR
Memory Recall
Description
This command recalls the load’s setup stored in the specified
memory location. The memory location number must be a value
from 1 through 6.
XBL Series 404078 Rev P2.odt Page 95 Of 162