#19 MASTER SLAVE IND
The LCD displays the current master, slave, or independent setting. This value may be changed
via the keypad and the ENTER key. The factory default setting is 0 (independent or stand alone
mode). The alternate settings are: 1 (slave mode) , 2 (master mode).
#20 SLEW RATE
The LCD displays the current slew rate setting. This value may be changed via the keypad and
the ENTER key. The factory default setting is 1 (normal – 100 usec 0 to FS). The alternate
settings are: 0 (slow -1 sec 0 to FS) and 2 (fast – 10 usec 0 to FS).
#21 UNDER VOLTAGE
The LCD displays the current under voltage setting. This value may be changed via the keypad
and the ENTER key. The factory default setting is 0 (VDC).
#22 VOLTAGE LIMIT
The LCD displays the current voltage limit setting. This value may be changed via the keypad
and the ENTER key. The factory default setting is the actual model voltage.
#23 CURRENT LIMIT
The LCD displays the current limit setting. This value may be changed via the keypad and the
ENTER key. The factory default setting is the actual model current.
#24 POWER LIMIT
The LCD displays the current power limit setting. This value may be changed via the keypad
and the ENTER key. The factory default setting is the actual model power.
#25 IWV
The LCD displays the current IWV setting. This value may be changed via the keypad and the
ENTER key. The factory default setting is 0 (amps). This command will instruct the unit to set
the programmed current only after sufficient voltage has been applied to the load.
#26 RESET
Selecting the ENTER key resets the load to it's default power on condition.
#27 SELF TEST
Selecting the ENTER key executes the unit's internal self test routine.