10. Maintenance

Periodically check all external cable connections.

11. Cleaning

Observe the safety instructions before cleaning the device. Clean the device with a
dry lint-free soft cloth. Do not use solvents.

12. Specification

Supply

12 - 24 V AC/DC ±10% (50/60 Hz ±10%)

Power consumption

Max. 1.2 W

Display

LCD graphic display 192 × 160 pixels,

16 grey levels

Measuring range voltage

±300 V AC/DC, 10 - 500 Hz

Accuracy voltage

±1 % true RMS

Internal resistance voltage

1.3 MΩ

Measuring range ampere

±10 A AC/DC and 5 A AC for current transformer,

10 - 500 Hz

Accuracy ampere

±1 % true RMS

Internal resistance ampere

5 mΩ

Measuring range frequency

10 - 1000 Hz

Accuracy frequency

±0.1 Hz

Measuring value update

5 Hz (32 kHz sampling rate)

Recording of measurement

36 seconds to 14 days,

180 internal memory locations

Connections
(measuring inputs)
- Wire gauge
- Wire strip length
- Pitch

0.2 – 2.5 mm² (28 - 12 AWG)

7 mm

5.08 mm

Connections (supply)
- Wire gauge
- Wire strip length
- Pitch

0.13 – 1.3 mm² (26 - 16 AWG)

6 - 7 mm

3.5 mm

Operating temperature

0 °C to +50 °C

Storage temperature

-20 °C to +70 °C

Operating altitude

0 to 2000 m above sea level

IP code

IP65 (front), IP00 (back)

Dimensions

72 mm × 72 mm × 34 mm

Panel cut-out

68 mm × 68 mm

Mounting depth

31 mm (with plugs, cable direction rear facing)

Net weight

107 g

-----

 7 / 8 

-----

Summary of Contents for Digalox DPM72-AV2

Page 1: ...is not isolated from the measurement circuit At the maximum current strength 10 A 500 mW of waste heat is generated at the current sense resistor The tip of the current sense resistor becomes very hot...

Page 2: ...an be displayed and reset using an external switch Measured values are recorded over a time span of 36 seconds up to 14 days The time base as well as the display of the measuring history can be switch...

Page 3: ...ric data display min max display auto scaling measurement mode 4 Supply voltage input 5 Interface optional 6 Mounting Carefully insert the device into the panel cut out Insert the mounting bracket fro...

Page 4: ...rrent and voltage direct Load max 10 A FF 10 A Digalox U U I U I N L max 300 V Current via current transformer Load Current transformer FF Digalox U U I U I N L max 10 A Current via current transforme...

Page 5: ...T J1 J6 To configure the upper scale caption connect J3 within 10 seconds after restart and disconnect it again The device switches to programming mode Prog appears in the display followed by the uppe...

Page 6: ...ged by alternately opening and closing J1 interval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next...

Page 7: ...0 500 Hz Accuracy ampere 1 true RMS Internal resistance ampere 5 m Measuring range frequency 10 1000 Hz Accuracy frequency 0 1 Hz Measuring value update 5 Hz 32 kHz sampling rate Recording of measurem...

Page 8: ...nstruments Digalox DPM72 EX2 USB interface 15 Contact information TDE Instruments GmbH Gewerbestra e 8 D 71144 Steinenbronn Phone 49 7157 20801 E mail info tde instruments de Internet www tde instrume...

Reviews: