Digalox

®

 DPM72-AV2

Instruction manual (Rev-2021-07)

Graphic panel meter for Volt & Ampere

Package contents:

Panel meter Digalox

®

 DPM72-AV2, mounting bracket,

5 jumpers, 2 instruction manuals (EN + DE)

1. Safety instructions

Read   instruction   manual   carefully   before   operating   the   device!   Keep   for   later
reference.

Mounting and installation must be carried out by suitably qualified and competent
persons only.

WARNING: The measurement inputs of the device can carry life-threatening
voltages!

WARNING: When working on the device hazardous voltages must not be
connected   to   the   device!   The   terminals   J1-J6   are   not   isolated   from   the
measuring circuit.

DANGER: When the USB port is connected, only voltages lower than 50 V
may be applied to the measurement inputs. The USB port is not isolated
from the measurement circuit.

At the maximum current strength (10 A), 500 mW of waste heat is generated at
the current sense resistor. The tip of the current sense resistor becomes very hot
(87 °C).   Maintain   the   appropriate   safety   distances   and   pay   attention   to   good
ventilation!

The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).

When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 250 V AC switches must be isolated for at
least 500 V.

Do not open the housing!

Do not use the device in the presence of explosive or flammable substances!

All cables carrying hazardous voltages must be secured with external separators.

2. Meaning of symbols

General warning sign
(Attention, observe the documentation!)

-----

 1 / 8 

-----

Summary of Contents for Digalox DPM72-AV2

Page 1: ...is not isolated from the measurement circuit At the maximum current strength 10 A 500 mW of waste heat is generated at the current sense resistor The tip of the current sense resistor becomes very hot...

Page 2: ...an be displayed and reset using an external switch Measured values are recorded over a time span of 36 seconds up to 14 days The time base as well as the display of the measuring history can be switch...

Page 3: ...ric data display min max display auto scaling measurement mode 4 Supply voltage input 5 Interface optional 6 Mounting Carefully insert the device into the panel cut out Insert the mounting bracket fro...

Page 4: ...rrent and voltage direct Load max 10 A FF 10 A Digalox U U I U I N L max 300 V Current via current transformer Load Current transformer FF Digalox U U I U I N L max 10 A Current via current transforme...

Page 5: ...T J1 J6 To configure the upper scale caption connect J3 within 10 seconds after restart and disconnect it again The device switches to programming mode Prog appears in the display followed by the uppe...

Page 6: ...ged by alternately opening and closing J1 interval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next...

Page 7: ...0 500 Hz Accuracy ampere 1 true RMS Internal resistance ampere 5 m Measuring range frequency 10 1000 Hz Accuracy frequency 0 1 Hz Measuring value update 5 Hz 32 kHz sampling rate Recording of measurem...

Page 8: ...nstruments Digalox DPM72 EX2 USB interface 15 Contact information TDE Instruments GmbH Gewerbestra e 8 D 71144 Steinenbronn Phone 49 7157 20801 E mail info tde instruments de Internet www tde instrume...