background image

L200Y SLIDING GATE OPERATOR USER

’S MANUAL 

10 

Single-button  switch  /  Keypad  (normally  open,  single-button  mode):  T,  G  (Not  used),  K 

(Open/stop/close), GND (Common) 

To install the keypad  attach one lead of  your keypad to 

‘K’ of terminal X7 and the other to the 

‘GND’. The keypad will function in single channel mode. 

   

C o n t r o l   b o a r d

t e r m i n a l   X 7

B u t t o n   s w i t c h
k e y p a d

G

T

GND

K

Com

Signal

NO

com

K

G

com

NO

Not used

   

Schematic diagram                    Wiring diagram 

NOTE: Two modes (three-button mode or single-button mode) you can select according to your 

order. 

15. Output power supply: +12V (DC +12V), COM (CO)

DET (Loop detector), I.R. (Infrared N.C) 

DET

COM

Out

COM

AC24V

AC24V

Terminal 
X5,No.11

Loop detector

Control board

COM

GND

+12V

Out

COM

DET

COM

+12V

Loop detector

Control board

Loop detector with DC input

Infrared with DC input

Control board

Infrared

Control board

Infrared

Terminal 
X5,No.11

AC24V

AC24V

COM

Out

COM

I.R

+12V

COM

I.R

COM

Out

+12V

GND

COM

Terminal 
X8, No.15

Terminal 
X8, No.15

Terminal 
X8, No.15

Terminal 
X8, No.15

Loop detector with AC input

Infrared with AC input

 

Schematic diagram 

16. Beeper: DC12V 

17. Learn button: AN 

18. Dip-switch 

19. Antenna: ANT 

 

 

 

 

 

 

Summary of Contents for L200Y

Page 1: ...ECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door Auto...

Page 2: ...S MANUAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 11 8 Ma...

Page 3: ...trol devices to be placed so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator shou...

Page 4: ...ushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure of the motor and worm is shown in Fig2 Output torque can be adjusted by pressure screw...

Page 5: ...essure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal protector will switch off the motor automatically in case of temperature is higher than 9...

Page 6: ...se the anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors Fig 5 Operator Base Mount the gate operator base to the concrete...

Page 7: ...determine the position Weld the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet t...

Page 8: ...6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 9 control board s...

Page 9: ...mit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 2...

Page 10: ...three button mode or single button mode you can select according to your order 15 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C DET COM Out COM AC24V AC24V Terminal X5 No 1...

Page 11: ...nds The learning process is finished Up to 100 remote controls may be used Erase remote controls To erase all existing remote controls press and hold AN button the beeper will ring release the button...

Page 12: ...ction has been set Cancel auto close function please turn on the first and the second DIP switch see Fig 9 terminal 18 to ON position Press the remote control button button 1 button 2 or button 3 that...

Page 13: ...IP switch 1 to OFF position immediately Thus the width and auto close function of pedestrian mode have been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Please...

Page 14: ...the limit direction is wrong Activities Covered in this section Remote control Single button mode With each press of the button the gate will close stop open or stop cycle External button switch not s...

Page 15: ...w to make the output torque of the operator meet your requirement that is the device should be powerful enough to move the gate and capable of making friction plate skidding when it is blocked The mot...

Page 16: ...se The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and term...

Reviews: