L200Y SLIDING GATE OPERATOR USER
’S MANUAL
13
﹡
Set auto-close function of pedestrian mode: Please turn on the first and the second
DIP-switch (See Fig.9 terminal 18) to ON position. Press button 4 to open the gate (see
Verify open direction
section), wait some seconds (3~10 sec.). Then press the same
button/button 4 to stop the gate, wait some seconds according to your requirements (1~44
sec.), this period of time is regarded as
‘auto-close time of pedestrian mode’. Close the
gate by pressing the same button/button 4. Press the same button again to stop the gate or
the gate will stop at its closed position automatically if the limit switch is reached. After this
setup is complete, return DIP-switch 1 to OFF position immediately. Thus the
auto-close
function of pedestrian mode
has been set.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width you have set in
Set width of pedestrian mode
section.
If you open the gate with button 4, the gate will stop at the new expected position that you
have set, after some seconds as what you have set, the gate will close automatically.
Cancel width / auto-close function of pedestrian mode
﹡
Cancel both width and auto-close function of pedestrian mode: Please turn on the first
and the second DIP-switch
(See Fig.9 terminal 18) to ON position. Press button 4 to open
the gate (see
Verify open direction
section). Wait for more than 15 sec.. Then press the
same button/button 4 to stop the gate. Wait until the gate close automatically (45 sec.),
press the same button/button 4 to stop the gate or the gate will stop at its closed position
automatically if the limit switch is reached. After this setup is complete, return DIP-switch 1
to OFF position immediately. Thus the width and auto-close function of pedestrian mode
have been cancelled.
﹡
Cancel width of pedestrian mode, keep auto-close function of pedestrian mode: Please
turn on the first and the second DIP-switch (See Fig.9 terminal 18) to ON position. Press
button 4 to open the gate (see
Verify open direction
section). Wait for more than 15 sec..
Then press the same button/button 4 to stop the gate. Wait some seconds according to
your requirements (1~44 sec.). Then press the same button/button 4 to close the gate,
press the same button again to stop the gate or the gate will stop at its closed position
automatically if the limit switch is reached. After this setup is complete, return DIP-switch 1
to OFF position immediately. Thus the width of pedestrian mode has been cancelled, the
auto-close function of pedestrian mode has been reserved.
Note: the new auto-close time of pedestrian mode has been re-programmed in the device
and replaced the original auto-close time of pedestrian mode that you have been set in
Set
auto-close function of pedestrian mode
section.
﹡
Keep width of pedestrian mode, cancel auto-close function of pedestrian mode: Please
turn on the first and the second DIP-switch (See Fig.9 terminal 18) to ON position. Press
button 4 to open the gate (see
Verify open direction
section). Wait some seconds (3~10
sec.), then press the same button/button 4 to stop the gate. Wait until the gate close
automatically (45 sec.). Press the same button again to stop the gate or the gate will stop
at its closed position automatically if the limit switch is reached. After this setup is complete,
return DIP-switch 1 to OFF position immediately. Thus the width of pedestrian mode has
been reserved, the auto-close function of pedestrian mode has been cancelled.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width.