Set auto-close function of pedestrian mode: Please turn on the first and the second 

DIP-switch (See Fig.9 terminal 18) to ON position. Press button 4 to open the gate (see 

Verify open direction

 section), wait some seconds (3~10 sec.). Then press the same 

button/button 4 to stop the gate, wait some seconds according to your requirements (1~44 

sec.), this period of time is regarded as 

‘auto-close time of pedestrian mode’. Close the 

gate by pressing the same button/button 4. Press the same button again to stop the gate or 

the gate will stop at its closed position automatically if the limit switch is reached. After this 

setup is complete, return DIP-switch 1 to OFF position immediately. Thus the 

auto-close 

function of pedestrian mode 

has been set.   

Note: the new width of pedestrian mode has been re-programmed in the device and 

replaced the original width you have set in 

Set width of pedestrian mode

 section. 

If you open the gate with button 4, the gate will stop at the new expected position that you 

have set, after some seconds as what you have set, the gate will close automatically.     

 

Cancel width / auto-close function of pedestrian mode 

Cancel both width and auto-close function of pedestrian mode: Please turn on the first 

and the second DIP-switch

 

(See Fig.9 terminal 18) to ON position. Press button 4 to open 

the gate (see 

Verify open direction

 section). Wait for more than 15 sec.. Then press the 

same button/button 4 to stop the gate. Wait until the gate close automatically (45 sec.), 

press the same button/button 4 to stop the gate or the gate will stop at its closed position 

automatically if the limit switch is reached. After this setup is complete, return DIP-switch 1 

to OFF position immediately. Thus the width and auto-close function of pedestrian mode 

have been cancelled. 

Cancel width of pedestrian mode, keep auto-close function of pedestrian mode: Please 

turn on the first and the second DIP-switch (See Fig.9 terminal 18) to ON position. Press 

button 4 to open the gate (see 

Verify open direction

 section). Wait for more than 15 sec.. 

Then press the same button/button 4 to stop the gate. Wait some seconds according to 

your requirements (1~44 sec.). Then press the same button/button 4 to close the gate, 

press the same button again to stop the gate or the gate will stop at its closed position 

automatically if the limit switch is reached. After this setup is complete, return DIP-switch 1 

to OFF position immediately. Thus the width of pedestrian mode has been cancelled, the 

auto-close function of pedestrian mode has been reserved. 

Note: the new auto-close time of pedestrian mode has been re-programmed in the device 

and replaced the original auto-close time of pedestrian mode that you have been set in 

Set 

auto-close function of pedestrian mode 

section. 

 

Keep width of pedestrian mode, cancel auto-close function of pedestrian mode: Please 

turn on the first and the second DIP-switch (See Fig.9 terminal 18) to ON position. Press 

button 4 to open the gate (see 

Verify open direction

 section). Wait some seconds (3~10 

sec.), then press the same button/button 4 to stop the gate. Wait until the gate close 

automatically (45 sec.). Press the same button again to stop the gate or the gate will stop 

at its closed position automatically if the limit switch is reached. After this setup is complete, 

return DIP-switch 1 to OFF position immediately. Thus the width of pedestrian mode has 

been reserved, the auto-close function of pedestrian mode has been cancelled. 

Note: the new width of pedestrian mode has been re-programmed in the device and 

replaced the original width. 

Summary of Contents for L200Y

Page 1: ...ECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door Auto...

Page 2: ...S MANUAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 11 8 Ma...

Page 3: ...trol devices to be placed so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator shou...

Page 4: ...ushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure of the motor and worm is shown in Fig2 Output torque can be adjusted by pressure screw...

Page 5: ...essure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal protector will switch off the motor automatically in case of temperature is higher than 9...

Page 6: ...se the anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors Fig 5 Operator Base Mount the gate operator base to the concrete...

Page 7: ...determine the position Weld the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet t...

Page 8: ...6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 9 control board s...

Page 9: ...mit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 2...

Page 10: ...three button mode or single button mode you can select according to your order 15 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C DET COM Out COM AC24V AC24V Terminal X5 No 1...

Page 11: ...nds The learning process is finished Up to 100 remote controls may be used Erase remote controls To erase all existing remote controls press and hold AN button the beeper will ring release the button...

Page 12: ...ction has been set Cancel auto close function please turn on the first and the second DIP switch see Fig 9 terminal 18 to ON position Press the remote control button button 1 button 2 or button 3 that...

Page 13: ...IP switch 1 to OFF position immediately Thus the width and auto close function of pedestrian mode have been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Please...

Page 14: ...the limit direction is wrong Activities Covered in this section Remote control Single button mode With each press of the button the gate will close stop open or stop cycle External button switch not s...

Page 15: ...w to make the output torque of the operator meet your requirement that is the device should be powerful enough to move the gate and capable of making friction plate skidding when it is blocked The mot...

Page 16: ...se The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and term...

Reviews: