background image

DKC1500 SERIES SLIDING GATE OPERATOR USER

’S MANUAL 

12 

path of the gate, as serious injury could result. Damage to the gate operator motors may also 

occur by placing a heavy immovable object in the path during the testing phase. Instead, place a 

light object in the path (e.g., a chair or trash can) which can be pushed out of the way without 

causing damage to gate motors. Once the tuning is complete you may replace the cover. 

 

External button switch (not included): two different modes you can select according 

to your order. 

 

Three-button external button switch: connect external button switch to 

terminal ‘K’, ‘T’, ‘G’ 

and 

‘GND’. Press ‘OPEN’ button, the gate will open. Press ‘STOP’ button, the gate will stop. 

Press 

‘CLOSE’ button, the gate will close.   

 

Single-button/keypad: connect keypad to ter

minal ‘OSC’ and ‘GND’, with each press of the 

button, the gate will close, stop, open or stop cycle.

 

 

Auto-close function: 

This feature can be selected to make the gate stay open for some 

seconds before it automatically closes. The auto-close time can be adjusted by DIP-switch.

 

 

Auto-close time 

1second 

10 seconds 

30 seconds 

Auto close function is 

unavailable 

Position 1 

ON 

OFF 

ON 

OFF 

Position 2 

OFF 

ON 

ON 

OFF 

WARNING: Infrared photocell must be used. 

 

Pedestrian mode

: Connect the pedestrian button switch to 

‘P’ and ‘GND’ terminal on the 

control board. Set auto close time first (auto-close time can be adjusted by DIP-switch), 

press the button 4 of remote control or pedestrian button switch, the gate will open about 

1.2 meters for people pass through, after passing through the gate, the gate will close 

automatically. 

 

Adjustment of opening & closing force:

 rotate the 

‘VR1’ (See Fig.11 terminal 7) knob 

with a screwdriver to adjust opening & closing force, the force may be increased (or 

decreased) by rotating clockwise (or counterclockwise). If you turn the variable resistor 

clockwise it will increase force. If you turn the variable resistor counterclockwise, it will 

decrease force.   

 

Adjustment of soft stop width: Rotate the 

‘VR2’ knob (See Fig.11 terminal 6) to adjust soft 

stop width, the width may be increased by rotating clockwise (soft stop width: 0-40cm 

adjustable). 

 

Infrared photocell (not included)

: If infrared beam is interrupted during closing, the gate 

will reverse and go open immediately. Connect infrared photocell to terminal 

‘IR’ and ‘GND’ 

on the control board. Short 

‘IR’ and ‘GND’ if infrared photocell is not used. 

 

Open priority:

 The gate will return to open if press 

‘OPEN’ button of external button switch 

during closing. 

 

Loop detector:

 connect loop detector (N.O.) to terminal block 

‘DET’ and ‘GND’ . 

If  loop  detector  detects  vehicles  during  closing,  the  gate  will  open  immediately  and  stay 

open until the vehicles move out of the loop. After vehicles move out of the loop, the gate 

will continue to close.

 

If loop detector detects vehicles when the gate stops, the gate will open immediately until 

vehicles move out of the loop. After vehicles move out of the loop, the gate will close.   

 

Soft start:

 snip the short wire 

‘S3’, the gate will start softly. 

Summary of Contents for DKC1500 Series

Page 1: ...CED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door...

Page 2: ...UAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Manual operation 4 6 Packing list 4 7 Installation and adjustment 5...

Page 3: ...mity to moving parts where hands or fingers could be pinched It is necessary to install the located blocks on two ends of guide Do not allow control devices to be placed so that a person can access th...

Page 4: ...manual release key to open or close gate manually use the release key as follow Fit the release key in the lock Turn the key about 4 6 circles anticlockwise Open or close the gate manually Note If the...

Page 5: ...2 Anchor bolts for mounting operator 4 3 Magnet 2 4 High low bracket 1 5 Block 1 optional 6 Release key 2 7 Remote control 2 7 Installation and adjustment Fig 3 The DKC1500 series rack driven gate ope...

Page 6: ...button switch we advise you to use two conduits one for main power wire another one for control wire Always separate power wires from control wires Concrete pad The base unit of the gate operator req...

Page 7: ...alled to ensure it meshes correctly with the gear The space between rack and gear is about 1 2mm Fig 6 Magnets for limit switch Install the magnet as shown in Fig 7 and Fig 8 below The magnet and limi...

Page 8: ...e rails must be installed horizontally Install the plastic block as shown in Fig 7 and a Fig 8 The spring limit switch and blocks are used to control the position of the gate Release the gear clutch w...

Page 9: ...lectrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 11 control board sche...

Page 10: ...Indicator light learn LED2 11 Receiver 12 MCU stm8s103 13 Limit switch N C OP open GND com CL close Snip short wire S2 Limit switch N O OP GND CL Wiring Open Com Close N C for N C limit switch Open C...

Page 11: ...erase all existing remote controls press and hold LEARN button about 8 seconds till the LED2 turns on and turns off This indicates that all the remote controls have been erased completely Warning For...

Page 12: ...button 4 of remote control or pedestrian button switch the gate will open about 1 2 meters for people pass through after passing through the gate the gate will close automatically Adjustment of openi...

Page 13: ...than 15 minutes If it is runs continually for an extended period of time a thermal protector will stop it because of the high temperature 10 Maintenance Ensure the operator is well earthed and correct...

Reviews: