Commissioning
!
First install the system completeley, then connect it to the power supply!
Install the devices of the system completely.
Do not connect V1 and V2 with P-, a- or b-wire. When connecting the video wires
V1 (+) and V2 (-) observe the polarity. If the video image is distorted after the com-
missioning, switch off the device and exchange the wires for the video signal.
Check the a-, b- and P-wire against each other on short-circuit.
Switch on the mains voltage.
Error detection and indication
Errors are signaled optically when detected and acoustically on keystroke: single error
tone and permanent flashing of the operation indication. When presssing any button of the
video indoor station IVW3012 the error tone sounds again. The optical error indication
stays active until the error is corrected.
error causes
indication
error
mode
error
tone
solution
a- and P-wire are mixed up
or short-circuited
blue ope-
ration
LED
flashes
exchange a- and P-wire or remove short-circuit,
device enters stand-by mode again
a- or M-wire: not connect-
ed or not supplied
connect a- resp. M-wire or check power supply,
device enters stand-by mode again
button clamps (pressed
longer than 15 sec)
release button at IVW3011 or floor push button, de-
vice enters stand-by mode again
Install the indoor station as end device
The indoor station is at the end of a strand or the only device on the strand:
Open the device. See
Disassembling the
device, page 12.
Put on the terminating resistor horizontally onto both contacts.
Delivery state: terminating resistor
not plugged
*(diagonal, plugged to one contact.
Close the device).