exceed the maximum of 8
Ω (table 1).
If the loop resistance exceeds 8
Ω: plan multiple wiring of the lines (double twisted
strands).
Optional strand or star formed wiring.
Do not use more than 6 video indoor stations per strand. For systems with more video
indoor stations plan the use of video distributors (FVY1200, FVY1400).
Up to 64 front-door stations (16 of them with video) and almost an unlimited number of
indoor stations can be connected polarity-free (a/b) within one system (polarity-free only
in 6-wire operation). For this, a suitable power supply and control unit has to be used.
Table 1: loop resistances
cable length
a-b/ M-P
in m
cable diameter
0.6 mm
0.8 mm
loop resistance
in Ω
10
1.22
0.69
20
2.45
1.38
30
3.67
2.07
40
4.90
2.76
50
6.12
3.44
60
7.35
4.13
70
4.82
80
5.51
90
6.20
100
6.89
Principle loop resistance
Measurement loop resistance
Rule:
None of the devices (AS, IS or FE) should each be
further than
8 Ohm
away from the power supply
control unit (VS).
Rule:
Switch off 230 V / 50 Hz of the VS.
Install a-b short-circuit at the VS.
All other devices do not disturb the measurement
and can stay connected.
8 Ohm:
around 65 m distance AS-VS by 0.6 mm diameter
around 115 m distance AS-VS by 0.8 mm diameter
short-circuit a, b