Scope of delivery
1 x indoor station IMM2300
(lower cover, upper cover of basic module, lower cover of video module)
1 x pluggable screw terminal
for connecting the video modules
product information
instruction manual
Safety instructions
!
Mounting, installation and commissioning have to be carried out only by qualified elec-
tricians!
When working in systems with 230 V mains voltage, the safety requirements according to
DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed:
separated cabling for heavy and low current lines,
minimum distance of 10 cm for common cablings,
use of separators between heavy and low current lines in shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross sections can be used in compliance
of the loop resistance.
!
With suitable requirements to protect against lightning, it has to be ensured that a vol-
tage of each 32 V DC is not exceeded at the TCS:BUS wires a and b.
General information on the cable routing in TCS video systems
Term
6-wire operation
Standard operating mode. Video operation in which two separated
masses (b and M) are used.
6-wire operation
The cable routing is determined by the given structural conditions and is only limited by the
length.