Mounting and installation 

 

mounting height 

For an optimum viewing angle we recommend a mounting height of 1.6 
meters (upper egde of the device over the ground). 
 
 

Install the lower cover 

 

!

 

Attention! 

The video indoor stations have to be (de-)installed only 

voltage-free! 

 

!

 

Please ensure not to over tighten the screws when installing the 
lower cover on uneven surfaces. Over tighten the screws might de-
form the lower cover. As a result the upper cover cannot be 
snapped-on the lower cover or the save contact between lower and 
upper cover might be affected. 

 
 

Installation with flush-mount 
or wall outlet socket 

  Always install the indoor sta-

tion on a flush-mounted 
socket or wall outlet socket. 
Position the cable gland over 
the socket. 
 

  Fix the lower cover via the 

attachment holes with suita-
ble screws on the flush-
mounted socket or to the wall 
according to the illustration. 

Illustration: lower cover (over flush-mounted 
socket) 

                        

 

 

2 screws over 
flush-mounted 
socket 

position flush-
mount socket 

4 screws for 
wall mounting 

Summary of Contents for Ecoos IVW2211-0140

Page 1: ...Product information video indoor station ecoos IVW2211 0140...

Page 2: ...2...

Page 3: ...5 Commissioning 16 Error detection and indication 16 Settings 17 Factory settings 17 AS address dependent image activation 17 Pre adjusted times 17 Configuration options 18 reload factory settings 18...

Page 4: ...buffer 27 Short messages 28 Read short messages 28 Delete short messages 29 General information on the conduit in TCS video systems 29 6 wire operation 29 Max number IVW2211 in 6 wire operation 31 FA...

Page 5: ...ral safety regulations for tel ecommunication systems according to VDE 0800 must be observed In ter alia separated cable routing of high and low voltage lines minimum distance of 10 cm in case of a co...

Page 6: ...ring tone Programming the bell buttons of the front door station can be realised with the Service Device TCSK 01 and configoTM On Screen Display OSD The menu which is shown on the screen and activat e...

Page 7: ...er and image parame ter via OSD door release button door release factory setting end communication trigger light switch function image button loudspeaker microphone navigation button UP navigation but...

Page 8: ...the start menu for im age buffer resp main menu image ring tone parameter menu or time setting is activated select parameter to change it main call internal call or control function menu or short mes...

Page 9: ...P reload factory settings indication LED red ON call OFF is activated flashes then OFF door release automatic or call diversion is activated indication LED green ON incoming door call or internal call...

Page 10: ...ed A system equipped with indoor stations IVW2211 is not an emer gency call system according to the above mentioned standards The system equipped with an indoor station IVW2211 must not be used in lif...

Page 11: ...can be activated via configo max 10 short messages can be received and displayed optical indication for new stored images in central image buffer FVM1000 optical short term memory of door calls optica...

Page 12: ...ower cover As a result the upper cover cannot be snapped on the lower cover or the save contact between lower and upper cover might be affected Installation with flush mount or wall outlet socket Alwa...

Page 13: ...r Terminal can be removed from the guide Put the lines in the designated ar ea Ensure that no uninsulated or not connected wire e g cable shield is placed in the device as this might cause short circu...

Page 14: ...the upper cover 2 Open the device There is a rectangular release opening at the underside of the device Insert a small screwdriver straight and with slight pressure into this opening The upper cover c...

Page 15: ...e M wire can not be connected you can use the de vice in 5 wire special operation Installing a wire bridge between the wires b and M is only permitted when observing some conditions For a solution for...

Page 16: ...indication Errors are signalled optically and acoustically single error tone and per manent flashing of both LEDs error cause indication error mode error tone our solution a and P wire are mixed or s...

Page 17: ...door call from max 16 video front door stations AS address as of 32 free for front door stations without camera the image is not activated in case of a door call The video AS border can be configured...

Page 18: ...determine video AS border and door call AS border x image activation in case of an in coming floor call floor video func tion x allocate short message groups x FVM1000 is always blocked x FVM1000 on...

Page 19: ...serial number of the indoor station to which the new configured indoor station is allocated General information on the OSD menu The navigation within the OSD menu the image buffer indication and live...

Page 20: ...lls 1 2 3 4 ring tone volume 0 1 2 display of adjusted values Help function To simplify the operation of the device help symbols are faded in in the upper right corner which show the available buttons...

Page 21: ...me is pre selected Press the navigation button UP or DOWN to adjust the volume The level of the ring tone volume 1 to 4 is displayed The adjusted ring tone sounds in the selected volume and is stored...

Page 22: ...ve image The symbols in the live image are faded in for 10 sec by activating the image after the image button was pressed or a door call has been received or for 3 sec after pressing the speech button...

Page 23: ...art menu can only be activated if the image buffer was activated via the configuration software configo see Image buffer page 25 no live image is displayed and the indoor station is in standby mode Th...

Page 24: ...nu ring tone selection for sub door ring tone 2 ring tone mute activated ring tone selection for sub door ring tone 3 menu short messages ring tone selection for sub door ring tone 4 screen to read a...

Page 25: ...atic image storing is not activated the color of the symbol image buffer is red Activate deactivate the automatic image storage Activation Press the menu button longer than 4 sec An acknowledgement to...

Page 26: ...enu button The main menu is displayed Select the symbol image buffer to display the image Browse through all new stored images with the navigation buttons UP or DOWN Image with date time image number...

Page 27: ...are available when a call comes in the information empty storage is displayed for 4 sec Then the main menu is displayed Set date and time of the image buffer This dialog only appears when the use of...

Page 28: ...on IVW2211 can receive short messages via the TCS BUS The messages can be stored and displayed Select receive short messages in the configuration software configo Max 10 short messages can be stored T...

Page 29: ...more short messag es have been received than can be stored the oldest message is overwrit ten automatically General information on the conduit in TCS video systems 6 wire operation 6 wire operation is...

Page 30: ...wer supply and control unit is to be used Table 1 loop resistances Length of the line a b M P in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 5...

Page 31: ...function Max number IVW2211 in 6 wire operation small and me dium sized systems max number IVW2211 AS front door station VS power supply and control unit IS indoor station T door opener Note The max...

Page 32: ...a switches over to black and white The camera module of the front door station is very insensitive to light Ensure that there is sufficient illumination or use an external camera The colours of the vi...

Page 33: ...ponent in a strand needs a matching resistor In one building block with multiple indoor stations only one indoor station shows black lines on the video image Image interferences due to transition resi...

Page 34: ...image When pressing the image button there is no respond No signal present Connect the monitor before the video switch and check if there is a signal Measure the voltage between P and b The voltage i...

Page 35: ...has to be disposed separately from domestic waste The materials used are recy clable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispo...

Page 36: ...ZIT1700 0016 Central image buffer FVM1000 0400 Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str 7 39307 Genthin GERMAN...

Reviews: