18
Event Management
This chapter describes the Event Management page.
In This Chapter
18.1
Associate events with output facilities
Event Management
On the Event Management page, you can configure how the BC840-MC is to handle incoming
events/alarms. The event sources listed under Available inputs can be routed to a CC output,
CC stream, or FTP push.
18.1.1
CC Output #
Item
Description
Available inputs
List of sources that can be selected as inputs for each of the two
contact closure outputs.
Selected inputs
Selected inputs are connected with a logical OR so that any one will
cause a remote contact to close.
Output control
Normal
Direction.
Invert
Force active
Always on (for testing purposes, for example).
Force inactive
Always off.
Output status
Inactive (open) or active (closed). Active: one or more of the selected
inputs is true. Inactive: none of the selected inputs is true.
127