background image

a

 1  Read these instructions.
2   Keep these instructions.
3   Heed all warnings.
4   Follow all instructions.
5   Do not use this apparatus near water.
6   Clean only with dry cloth.
7   Do not block any ventilation openings. Install in accordance 

with the manufacturer’s instructions.

8   Do not install near any heat sources such as radiators, heat 

registers, stoves, or other apparatus (including amplifiers) 
that produce heat.

9   Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug has two blades 
and a third grounding prong. The wide blade or the third prong 
are provided for your safety. If the provided plug does not fit 
into your outlet, consult an electrician for replacement of the 
obsolete outlet.

10   Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the point 
where they exit from the apparatus.

11   Only use attachments/accessories specified by the 

manufacturer.

12  

Use only with the cart, stand, tripod, bracket, or table 

specified by the manufacturer, or sold with the apparatus. 
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.

13   Unplug this apparatus during lightning storms or when unused 

for long periods of time. 

14  Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way, 
such as cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has 
been dropped.

• 

This equipment should be installed near the socket outlet and 

disconnection of the device should be easily accessible.

• 

To completely disconnect from AC mains, disconnect the 

power supply cord from the AC receptacle.

• 

The mains plug of the power supply shall remain readily 

operable.

• 

Do not install in a confined space.

• 

Do not open the unit – risk of electric shock inside.

Caution:

 

You are cautioned that any change or modifications not 
expressly approved in this manual could void your authority to 
operate this equipment.

Service

• 

There are no user-serviceable parts inside. 

• 

All service must be performed by qualified personnel.

Warning!

• 

To reduce the risk of fire or electrical shock, do not expose 

this apparatus to rain or moisture and objects filled with 
liquids, such as vases, should not be placed on this apparatus.

• 

This apparatus must be earthed.

• 

Use a three wire grounding type line cord like the one supplied 

with the product.

• 

Be advised that different operating voltages require the use of 

different types of line cord and attachment plugs.

• 

Check the voltage in your area and use the correct type. 

 

See table below:

Voltage   Line plug according to standard
110-125V  UL817 and CSA C22.2 no 42.
220-230V  CEE 7 page VII, SR section  

 

 

 

107-2-D1/IEC 83 page C4.

240V 

BS 1363 of 1984. Specification for 13A  

 

 

fused plugs and switched and    

 

 

unswitched socket outlets.

The lightning flash with an arrowhead symbol within an 
equilateral triangle is intended to alert the user to the 
presence of uninsulated “dangerous voltage” within the 
product’s enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the 
literature accompanying the product.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for Desktop Konnekt 6

Page 1: ...User s Manual English Version Desktop Konnekt 6...

Page 2: ...ipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply cord from the AC recept...

Page 3: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incre...

Page 4: ...r top notch sound quality Desktop Konnekt 6 s unique design not only makes it fit perfectly onto your desktop for easy operation it will also make you want to leave it right next to your laptop just f...

Page 5: ...Control Panel On Mac computers Applications TC Near You may also start the application from System Preferences On Windows computers Press Start Programs TC Electronic TC Near The TC Near Control pane...

Page 6: ...rols the phones level However via the Setup page it is possible to link the phones level to the big volume knob on the front panel Separate level control is ideal such as when you are in the control r...

Page 7: ...ST 1 4 jack inputs When you work with a variety of recording sources you do not have to change the routing every time You can leave microphone and instruments connected to the three recording inputs a...

Page 8: ...l the time Input selection is done using the SCENE buttons FRONT PANEL OVERVIEW REAR PANEL OVERVIEW 13 12 11 Phones level Individual levels can be set for the Phones and Monitor outputs This knob sets...

Page 9: ...as you wish Simply click on the channel label and enter a name of your choice MIXER PAGE MIXER PAGE 15 14 CONTROL PANEL Press the Mixer tab to enter the Mixer page To change position of knobs and fade...

Page 10: ...he A B button you will toggle between these two memory locations The A B memory locations are temporary settings only Saving a preset will save the currently selected memory location only The setting...

Page 11: ...AW 13 100 Deactivates the mix control and sets a 100 wet mix This is the setting to use when you are using the M40 reverb as a send effect and also when using it as a cue reverb for recording When usi...

Page 12: ...the Setup page Disabling the Reverb Control will of course have no influence on the VST AU version of the M40 Studio Reverb The reverb section on the mixer page will then show 7 Reverb Control Reverb...

Page 13: ...48 units connected via FireWire a computer and an ADAT interface We assigned the nicknames SK48 No1 and SK48 No2 to the two Studio Konnekt 48 units Nicknames are set on the Setup page The intention is...

Page 14: ...tudio Konnekt 48 will auto coast and immediately shift to the latest received valid clock rate AUTO INTERNAL NO REFERENCE This message appears when a valid external reference sync source has not been...

Page 15: ...units will appear in this drop down menu Output Assuming that Desktop Konnekt 6 is the only Konnekt device connected to your computer you can select between the following output channels for each outp...

Page 16: ...licking it Follow the instructions For detailed instructions on software installation please see the Installation guide included in the product box Updating Firmware Firmware is a computer program tha...

Page 17: ...dB 20 Hz to 20 kHz 1 4 Phone Jack Ground Sensing Design 100 Ohm 100 dBu to 13 dBu 95 dB 0 002 1 kHz 1 dBFS 102 dB 20 Hz to 20 kHz 0 0 1 dB 20 Hz to 20 kHz 100 dB 20 Hz to 20 kHz DAC D to A Conversion...

Reviews: