29
10. TECHNICAL SPECIFICATIONS
Parameter
Expert Modular
Supply voltage range
7..70Vdc
Supply current (@ 12V/ 24V/48V)
10mA / 6mA / 5mA
Input voltage range main battery (+B1)
7..70Vdc
1)
Input voltage range second and third battery (+B2,
+B3)
1..70Vdc
Input current range
-600..+600A
2)
Battery capacity range
10..10000Ah
Operating temperature range
-20..+50°C
Storage temperature range
-30..+70°C
Readout resolution: Voltage (0..70V)
Current (0..10A)
Current (10..100A)
Current (100..600A)
State of Charge (0..100%)
Time remaining (0..24hrs)
Time remaining (24..240hrs)
Amphours (0..10000Ah)
Power (0..42kW)
Temperature (-20°C..+50°C)
± 0.01V
± 0.01A
± 0.1A
± 1A
± 1%
± 1min
± 1hr
± 0.01Ah..10Ah (variable)
± 0.01W..1kW (variable)
± 0.5°C
Voltage measurement accuracy
± 0.3%
Current measurement accuracy
± 0.4%
Shunt dimensions:
Footprint
Base height
Total height
Weight
100 x 100mm
24.0mm
64.5mm
290grams
Display dimensions: Front panel
Body diameter
Total depth
Weight
Ø 64.0mm
Ø 51.5mm
36.0mm
70grams
Protection class
IP20 (shunt vertically mounted)
IP65 (CDU front panel only)
Standards
CE certified (EMC Directive 2014/30/EU)
including EN50498 Automotive EMC
All specifications are subject to change without notice
1)
When input +B1 is only used for supply and +B2 for main battery voltage measurement, the
input voltage range for the main battery is 1..70Vdc.
2)
+/- 600A is the maximum rating for 20 minutes. The continuous input current range is
+/- 500A.
Please act according to your local rules and do not dispose of your old products
with the normal household waste. The correct disposal of your old product will
help prevent potential negative consequences for the environment and human
health.
Summary of Contents for Expert Modular
Page 2: ...2...
Page 4: ...4 English Page 5 Nederlands Pagina 32 Deutsch Seite 59 Francais Page 88 Espa ol P gina 117...
Page 5: ...5 Owner s manual...
Page 35: ...35 Gebruiksaanwijzing...
Page 65: ...65 Bedienerhandbuch...
Page 97: ...97 Mode d emploi...
Page 129: ...129 Manual del propietario...