16
S 4.0
Total hours. Shows the number of hours that this product has been running.
S 4.1
Maintenance hours. Shows the number of hours left before maintenance is
required.
S 4.3
Hours since charged. Shows the number of hours since the battery has last been
charged.
S 4.4
Hours since synchronized. Shows the number of hours since the battery monitor
has last been synchronized with the main battery.
5. HISTORY MENU
The History menu is a read only menu that shows the Expert Modular
’s History data.
History data are
special events that are stored in internal memory. This menu can be accessed by the following
sequence:
When the History menu is entered, you can use the left and right arrow keys to browse through the
different History items. By pressing the MENU key, the selected History item can be viewed. Pressing
the MENU key again, will then step back to the History menu. From any menu position, the Normal
Operating Mode can be accessed again by pressing the MENU key for 3 seconds. The following
History menu items are available:
Table 6
History item
History description
H 1.0
Average discharge (Ah). Average discharge of your main battery in Ah. This
number will be recalculated after each synchronization.
H 1.1
Average discharge (%). Average discharge of your main battery in percent. This
number will be recalculated after each synchronization.
H 1.2
Deepest discharge (Ah). Deepest discharge of your main battery in Ah.
H 1.3
Deepest discharge (%). Deepest discharge of your main battery in %.
H 1.4
Total Ah removed. The total number of Amphours removed from the main
battery. When exceeding 999Ah, the units change to kAh and the displayed
value must be multiplied by 1000.
H 1.5
Total Ah charged. The total number of Amphours charged to the main battery.
When exceeding 999Ah, the units change to kAh and the displayed value must
be multiplied by 1000.
H 1.6
Total kWh removed. The total number of kWh removed from the main battery.
When exceeding 999kWh, the units are changed to MWh.
H 1.7
Total kWh charged. The total number of kWh charged to the main battery.
When exceeding 999kWh, the units are changed to MWh.
H 1.8
Cycle count. The number of charge / discharge cycles.
H 1.9
Synchronization count. The number of synchronizations.
H 2.0
Alarm 1 count. The number of times Alarm 1 has been triggered.
Summary of Contents for Expert Modular
Page 2: ...2...
Page 4: ...4 English Page 5 Nederlands Pagina 32 Deutsch Seite 59 Francais Page 88 Espa ol P gina 117...
Page 5: ...5 Owner s manual...
Page 35: ...35 Gebruiksaanwijzing...
Page 65: ...65 Bedienerhandbuch...
Page 97: ...97 Mode d emploi...
Page 129: ...129 Manual del propietario...