Solubility in water 

(solid, 1 bar)  1.6 g/L at 20°C , 3.2 g/L at 0°C 

Solubility in water 

(gas, 1 bar)    0.5 mg/L at 20°C , 1,0 mg/L at 0°C 

Critical temperature 

31°C 

Critical pressure 

74.0 bar 

Heat capacity c

p

 

0.83 kJ/(kg K) 

 

 

   Safety statements 

 

R/S phrases 

R: - , S: 9, 23 

MAK 

5000 ppm (9.9 g/m³) 

 

 

SI units are used where possible and common. 

If not noted otherwise, standard conditions apply. 

 
 

 

 

 

Physiological effects and dangers of carbon dioxide 

 

CO

concentrations (vol-%) in breathing air and impacts on health: 

 

0.038%: carbon dioxide content in fresh air 

 

0.15%: recommended sanitary value for interior fresh air 

 

0.3%:  

MIK-level, no impacts on health in constant exposition below 

this level 

 

0.5%  (9g/m³): MAK-threshold level for daily exposition of up to 8 hours 

 

1.5% : increase of breathing time volume of more than 40% 

 

4%:   exhaled breathing air 

 

5%:   appearance of headaches, dizziness and unconsciousness 

 

8%:   unconsciousness; suffocation after 30-60 minutes 

 

 
 

 

 
 

 
 

 
 

 

TBF-PyroTec GmbH 
Lichterfelder Str. 5 A 

21502 Geesthacht 

Tel.: + 49 (0)4152 157 9950 
Fax: + 49 (0)4152 157 9951 

Summary of Contents for Jet-Master CO2

Page 1: ...1 CO2 Jet Master Safety instructions and operation manual J JE ET T M Ma as st te er r...

Page 2: ...sport and storage Check the incoming goods for damage and completeness Notify the shipper immediately of any transport damage The parts must be unpacked with great care and caution to prevent damage t...

Page 3: ...r the assembly and operation of the device The usage of other parts can lead to severe damage to persons or property 3 Start up The initial operation may only be carried out after complete assembly of...

Page 4: ...tbite and irreversible damage CO2 gas is heavier than air and may accumulate in low ceiling spaces causing deficiency of oxygen Danger of suffocation Ensure sufficient ventilation when installing the...

Page 5: ...d winds see safety instructions 3 Components of the unit The unit consists of Jet Master CO2 high pressure hose and Power cable 5 m 4 System Functionality After connecting the Jet Master to a CO2 pres...

Page 6: ...230 V AC Now the DMX channel can be set The Jet Master is equipped with a safety function Triggering the Jet Master is only possible if the device is unlocked via DMX The selected DMX channel indicate...

Page 7: ...e dry ice may form between the valve seating and the valve gasket This ice will evaporate quickly thus not compromising the valve s functionality Maintenance should be carried out annually please make...

Page 8: ...carbon dioxide CO2 concentrations vol in breathing air and impacts on health 0 038 carbon dioxide content in fresh air 0 15 recommended sanitary value for interior fresh air 0 3 MIK level no impacts o...

Reviews: