background image

 

Sufficient  safety  distance,  especially  to  personnel,  must  be  considered 
when assembling the device. Performers and participants must be clear of 

the safety distances beforehand, and the operation must be rehearsed. In 
dangerous situations the device must immediately be shut down! 

 

The sideway safety distance in still air is 2 m. 
The safety distance above the nozzle is 7 m. 

 
 

Maintenance  on  the  device  may  only  be  performed  by  the  qualified 

personnel  of  the  manufacturer.  The  casings  of  the  Jet-Master  or  the 
control panel must not be opened. Risk of electric shock! 

By  opening  the  casings  of  the  Jet-Master  or  the  control  panel  any 
guarantee  and/or  warranty  expires  and  we  assume  no  liability  for 

consequential accidents and damage to persons and/or property. 

 
 

Only original parts  from the manufacturer may be  used for the assembly 
and operation of the device. The usage of other parts can lead to severe 

damage to persons or property. 

 

 

 

3. Start-up 

 
 

The initial operation may only be carried out after complete assembly of all 

necessary  components  and  safeguards  by  trained  personnel,  in 
consideration  of  all  topics  addressed  in  these  safety  instructions  and  the 

operating  manual.  We  disclaim  liability    for  faulty  start-up  carried  out  by 
an untrained third party, and the warranty expires. 

 

 
 

4. Operation 
 

 

ATTENTION:  DO  NOT  TRIGGER  THE  Jet-MASTER  LONGER  THAN  5 
MINUTES! 

 
 

The operation of the unit is only allowed for the designated purpose, within 

the boundaries of design, by trained personnel. We assume no liability for 
inappropriate  use,  which  can  lead  to  severe  damage  to  persons  and/or 

property. Furthermore, warranty expires. 

 

 

In  dangerous  situations  the  device  must  immediately  be  shut  down  and 
disconnected from the power source. 

 
 

Make  sure  that  all  high-pressure  hoses  and  connections  are  intact. 
Defective or damaged parts must not be used. 

Summary of Contents for Jet-Master CO2

Page 1: ...1 CO2 Jet Master Safety instructions and operation manual J JE ET T M Ma as st te er r...

Page 2: ...sport and storage Check the incoming goods for damage and completeness Notify the shipper immediately of any transport damage The parts must be unpacked with great care and caution to prevent damage t...

Page 3: ...r the assembly and operation of the device The usage of other parts can lead to severe damage to persons or property 3 Start up The initial operation may only be carried out after complete assembly of...

Page 4: ...tbite and irreversible damage CO2 gas is heavier than air and may accumulate in low ceiling spaces causing deficiency of oxygen Danger of suffocation Ensure sufficient ventilation when installing the...

Page 5: ...d winds see safety instructions 3 Components of the unit The unit consists of Jet Master CO2 high pressure hose and Power cable 5 m 4 System Functionality After connecting the Jet Master to a CO2 pres...

Page 6: ...230 V AC Now the DMX channel can be set The Jet Master is equipped with a safety function Triggering the Jet Master is only possible if the device is unlocked via DMX The selected DMX channel indicate...

Page 7: ...e dry ice may form between the valve seating and the valve gasket This ice will evaporate quickly thus not compromising the valve s functionality Maintenance should be carried out annually please make...

Page 8: ...carbon dioxide CO2 concentrations vol in breathing air and impacts on health 0 038 carbon dioxide content in fresh air 0 15 recommended sanitary value for interior fresh air 0 3 MIK level no impacts o...