background image

 

7.

 

In case of emergency 

 

If serious malfunctions occur that pose a threat to persons and property, the 
device must immediately be shut down.  

Unplug  the  power  cable.  Then  immediately  close  the  hand  valve  of  the  CO

2

 

pressure cylinder. 

 

 
 

8.

 

 Care, maintenance and storage 

 

The unit is mostly maintenance-free. After long periods of operation  and 

frequent use, the electromagnetic valve may become leaky. This is noticeable 
by a constant hissing noise, which becomes louder every time the unit is 

operated.  

Short hissing noises, however, are normal, as some dry ice may form 
between the valve seating and the valve gasket. This ice will evaporate 

quickly, thus not compromising the valve's functionality. 
Maintenance  should  be  carried  out 

annually

,  please  make  an  appointment 

with the manufacturer, or send the unit in.  

 

 

 

9.

 

 Technical specifications 

 

Dimensions: 

 

approx. 20 x 20 x 23 cm 

Weight:   

 

4 kg 

Power input: 

 

230V AC, 50~60Hz 

Power consumption:  8W 

 

 

10.

 

CARBON DIOXIDE  

 

General 

Name 

Carbon dioxide 

Other names 

Carbonic acid gas, Carbonic anhydride 

Molecular formula 

CO

CAS No 

124-38-9 

Appearance 

odorless, colorless gas (compressed and liquefied) 

 

 

Properties 

Molar mass 

44,0099 g/mol  

Density 

1.98 kg/m³;  1,600 g/L 

Melting point 

-56.6°C (at 5.81 bar) 

Sublimation point 

-78.5°C 

Vapor pressure  

57.3 bar / 5730 kPa at 20°C 

Summary of Contents for Jet-Master CO2

Page 1: ...1 CO2 Jet Master Safety instructions and operation manual J JE ET T M Ma as st te er r...

Page 2: ...sport and storage Check the incoming goods for damage and completeness Notify the shipper immediately of any transport damage The parts must be unpacked with great care and caution to prevent damage t...

Page 3: ...r the assembly and operation of the device The usage of other parts can lead to severe damage to persons or property 3 Start up The initial operation may only be carried out after complete assembly of...

Page 4: ...tbite and irreversible damage CO2 gas is heavier than air and may accumulate in low ceiling spaces causing deficiency of oxygen Danger of suffocation Ensure sufficient ventilation when installing the...

Page 5: ...d winds see safety instructions 3 Components of the unit The unit consists of Jet Master CO2 high pressure hose and Power cable 5 m 4 System Functionality After connecting the Jet Master to a CO2 pres...

Page 6: ...230 V AC Now the DMX channel can be set The Jet Master is equipped with a safety function Triggering the Jet Master is only possible if the device is unlocked via DMX The selected DMX channel indicate...

Page 7: ...e dry ice may form between the valve seating and the valve gasket This ice will evaporate quickly thus not compromising the valve s functionality Maintenance should be carried out annually please make...

Page 8: ...carbon dioxide CO2 concentrations vol in breathing air and impacts on health 0 038 carbon dioxide content in fresh air 0 15 recommended sanitary value for interior fresh air 0 3 MIK level no impacts o...

Reviews: