User Manual of Solar Intelligent Energy System (SIES)
TBB Power Confidential Page
8
of
66
Table 7 Functions of MEDU
Category
Functions
AC input
Measure voltage, current, frequency, power and KWh
AC output
Measure voltage, current, frequency, power and KWh
Battery
Measure SoC, charging and discharging current, voltage, temperature,
charging and discharging KWh
Load
management
Measure the power and KWh of programmable AC output L2 and L3.
Users or installers can program the work logic of two AC outputs L2 and L3,
based on multiple conditions: length of time, power, battery SoC, interlock and
consumed energy in KWh.
2.6 Cyber central monitor
Thanks to T-Bus communication protocol, Cyber can display the work status of all system
components in real time, including PV array, inverter charger combination, battery and loads.
In the middle of LCD screen of Cyber, there are two green triple arrows and one blue triple arrow
which indicate the energy flows. These two energy flow bars display the system status in real time,
and are explained in detail in chapter 6.
Figure 2 Cyber the central monitor of SIES
Table 8 Functions of Cyber
Category
Functions
Monitoring
Energier Pro bi-directional inverter, Solar Mate MPPT charge controller,
Battery and Load
Configuration
Battery Type, Battery Capacity
Control
Battery Equalization
Communication
Built-in Bluetooth, optional GPRS or WIFI
Others
Calendar, Clock