background image

                                                                                                           

Bi1248

1200

 

User

 

Manual

 

 

1

1.

 

General

 

Safety

 

Instruction

 

1.1

 

Safety

 

Instruction

 

As

 

dangerous

 

voltages

 

and

 

high

 

temperature

 

exist

 

within

 

Bi1248

1200,

 

only

 

qualified

 

and

 

authorized

 

maintenance

 

personnel

 

are

 

permitted

 

to

 

open

 

and

 

repair

 

it.

 

Please

 

make

 

sure

 

Bi1248

1200

 

is

 

turned

 

off

 

before

 

open

 

and

 

repair

 

it.

 

This

 

manual

 

contains

 

information

 

concerning

 

the

 

installation

 

and

 

operation

 

of

 

Bi1248

1200.

 

All

 

relevant

 

parts

 

of

 

the

 

manual

 

should

 

be

 

read

 

prior

 

to

 

commencing

 

the

 

installation.

 

Please

 

follow

 

the

 

local

 

stipulation

 

meantime.

   

Any

 

operation

 

against

 

safety

 

requirement

 

or

 

against

 

design,

 

manufacture,

 

safety

 

standard,

 

and

 

are

 

out

 

of

 

the

 

manufacturer

 

warranty.

   

1.2

 

General

 

Precaution

 

Do

 

not

 

expose

 

to

 

dust,

 

rain,

 

snow

 

or

 

liquids

 

of

 

any

 

type

it

 

is

 

designed

 

for

 

indoor

 

use.

 

DO

 

NOT

 

block

 

off

 

ventilation,

 

otherwise

 

Bi1248

1200

 

would

 

be

 

overheating.

 

To

 

avoid

 

fire

 

and

 

electric

 

shock

make

 

sure

 

all

 

cables

 

selected

 

with

 

right

 

gauge

 

and

 

being

 

connected

 

well.

 

Smaller

 

diameter

 

and

 

broken

 

cable

 

are

 

not

 

allowed

 

to

 

use.

 

Please

 

do

 

not

 

put

 

any

 

inflammable

 

goods

 

near

 

to

 

Bi1248

1200.

 

Never

 

place

 

Bi1248

1200

 

directly

 

above

 

batteries,

 

gases

 

from

 

a

 

battery

 

will

 

corrode

 

and

 

damage

 

it.

 

Do

 

not

 

place

 

battery

 

over

 

Bi1248

1200.

 

1.3

 

Precaution

 

regarding

 

battery

 

operation

 

Use

 

plenty

 

of

 

fresh

 

water

 

to

 

clean

 

in

 

case

 

battery

 

acid

 

contacts

 

skin,

 

clothing,

 

or

 

eyes

 

and

 

consult

 

with

 

doctor

 

as

 

soon

 

as

 

possible.

 

The

 

battery

 

may

 

generate

 

flammable

 

gas

 

during

 

charging.

 

NEVER

 

smoke

 

or

 

allow

 

a

 

spark

 

or

 

flame

 

in

 

vicinity

 

of

 

a

 

battery.

 

Do

 

not

 

put

 

the

 

metal

 

tool

 

on

 

the

 

battery;

 

spark

 

and

 

short

 

circuit

 

might

 

lead

 

to

 

explosion.

 

REMOVE

 

all

 

personal

 

metal

 

items

 

such

 

as

 

rings,

 

bracelets,

 

necklaces,

 

and

 

watches

 

while

 

working

 

with

 

batteries.

 

Batteries

 

can

 

cause

 

short

circuit

 

current

 

high

 

enough

 

to

 

make

 

metal

 

melt,

 

and

 

could

 

cause

 

severe

 

burns.

   

Summary of Contents for Bi1248-1200

Page 1: ...Bi1248 1200 User Manual TBB Power Co Ltd Bi directional Converter Charger Bi1248 1200 User Manual Version A1 0 Date Dec 2019...

Page 2: ...0 User Manual TBB Power Co Ltd WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TABLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MAD...

Page 3: ...or choosing our products and this manual were suitable for DC DC Bi directional Converter Bi1248 1200 This chapter contains important safety and operation instructions Read and keep this User Guide we...

Page 4: ...nstallation Configuration 5 4 1 Unpacking inspection 6 4 2 Installation requirements 5 4 3 Cable preparation 5 5 Installation 5 5 1 Installation recommendations and operations 6 5 1 1 Installation dra...

Page 5: ...therwise Bi1248 1200 would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to...

Page 6: ...voltage is lower than 12 8V this device will stop working Smart alternator Euro 6 Through dip switch this device can be set to smart alternator mode After choosing this mode IGN signal or similar sig...

Page 7: ...tor Multiple battery chemical can be chose including lithium battery TBB premium II multiple stages charging algorithm Built in automatic temperature and voltage compensated charging Thermal controlle...

Page 8: ...Bi1248 1200 User Manual 4 3 Structure 3 1 Dimension 306 3282 8 170 291 6 85 200 4 5 301 6 Dimension 306 3 200 85mm Weight 3kgs...

Page 9: ...ethod air cooling Altitude 2000m or less meeting the derating requirements of GB3859 2 93 4 3 Cable and Fuse preparation Please refer to the table below for cable and fuse specifications Model Connect...

Page 10: ...off the power switch or external control signal to prevent Bi1248 1200 from working due to which may cause sparkling during the wiring process Please select the appropriate location with adequate vent...

Page 11: ...is 100A 3 12V terminal Positive terminal of starter battery the maximum current is 200A 4 BAT terminal Negative terminal of starter battery the maximum current is 100A 5 BAT terminal Negative termina...

Page 12: ...1 2 Battery Type setting OFF OFF AGM default OFF ON GEL ON OFF LFP ON ON OTHER 3 Alternator setting OFF Normal alternator ON Smart generator Euro 6 4 5 System working mode OFF OFF Stand alone mode ON...

Page 13: ...rminal BAT first and then connect the positive terminal 48V of the auxiliary battery and the positive terminal 12V of the starter battery respectively Connect one end of the negative cable to the term...

Page 14: ...RY_DO_NO1 Dry contact output normally open contact 10 DRY_DO_NO2 11 DRY_DI_NO1 Dry contact input normally open contact 12 DRY_DI_NO2 13 TEMP_BAT1 Service battery temperature sampling line 14 TEMP_BAT1...

Page 15: ...is strictly prohibited Check if the voltage and temperature compensation lines have been connected to the positive terminal of service battery If the generator is a smart generator confirm that the D...

Page 16: ...ndby Off others Boost mode Green On 12V battery is normal 12V battery charges 48V battery Flash standby Off others Alarm Orange Flash overheating of the radiator over temperature of the battery overvo...

Page 17: ...ard battery charging curve Battery types and bulk charging absorption charging voltage Table 8 Service battery types and bulk charging absorption charging voltage No Battery types Bulk charging voltag...

Page 18: ...e rating curve This device has built in intelligent temperature control and will reduce its output power in case of high working temperature reached Figure 8 Bi1248 1200 internal temperature and outpu...

Page 19: ...25A 100A Efficiency Max 94 Full load 91 Standby consumption 2mA Protection Input overvoltage alarm 14 9Vdc protection 16Vdc alarm 59 6V protection 60Vdc Output overvoltage alarm 59 6V protection 60Vd...

Page 20: ...Bi1248 1200 User Manual 16 TBB Power Co Ltd Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070 Email service tbbpower com...

Reviews: